Literature DB >> 15724759

Influence of different dentin etching times and concentrations and air-abrasion technique on dentin microtensile bond strength.

Fernando Ahid1, Marcelo F Andrade, Edson A Campos, Fabrício Luscino, Luis G Vaz.   

Abstract

PURPOSE: To determine the influence of different dentin treatments on the microtensile bond strengths of adhesive resins to dentin.
METHODS: Fifteen human molars were ground to 600-grit to obtain flat root-dentin surfaces. Five different dentin treatments were evaluated: Group 1--10% phosphoric acid for 30 seconds; Group 2--37% phosphoric acid for 15 seconds; Group 3--air-abrasion for 10 seconds followed by 10% phosphoric acid for 30 seconds; Group 4--air-abasion for 10 seconds followed by 37% phosphoric acid for 15 seconds. The dental adhesive (OptiBond Solo Plus) was applied according to manufacturer's instructions and followed by composite (Z100) application to provide sufficient bulk for microtensile bond testing. All samples were placed in distilled water for 24 hours at 37 degrees C, thermocycled for 500 cycles in distilled water at 10 degrees C and 50 degrees C, and serially sliced perpendicular to the adhesive surface and subjected to tensile forces (0.5 mm/minute). Additional samples were prepared for SEM to observe the adhesive interface.
RESULTS: Group 2 exhibited significantly (P < 0.05) lower bond strength values than all other treatments. The bond strengths of the different conditions were (in MPa): Group 1: 43.0 +/- 16.1; Group 2: 29.2 +/- 8.3; Group 3: 48.1 +/- 14.2; Group 4: 41.0 +/- 9.3. The dentin treated with phosphoric acid 37% for 15 seconds showed the lowest values of microtensile bond strength. The results obtained with Groups 1, 3 and 4 were statistically similar.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15724759

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  4 in total

1.  Analysis of surfaces and adhesive interfaces of enamel and dentin after different treatments.

Authors:  Michelle Alexandra Chinelatti; Silmara Aparecida Milori Corona; Maria Cristina Borsatto; Lilian Faria Ribeiro; Renata Andréa Salvitti de Sá Rocha; Regina Guenka Palma-Dibb
Journal:  J Mater Sci Mater Med       Date:  2007-03-27       Impact factor: 3.896

2.  Comparison between three glass fiber post cementation techniques.

Authors:  Guido Migliau; Luca Piccoli; Stefano Di Carlo; Giorgio Pompa; Laith Konstantinos Besharat; Marco Dolci
Journal:  Ann Stomatol (Roma)       Date:  2017-07-03

3.  Evaluation of over-etching technique in the endodontically treated tooth restoration.

Authors:  Guido Migliau; Luca Piccoli; Laith Konstantinos Besharat; Stefano Di Carlo; Giorgio Pompa
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

4.  [Effects of bond strength evaluation on different durations of adult permanent teeth and youth permanent teeth by using universal adhesives to dentin].

Authors:  Yuan Sun; He Liu; Zhi-Hui Sun
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-10-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.