Performance of coincidence imaging with long-lived positron emitters as an alternative to dedicated PET and SPECT.

Mattias Sandström1, Vladimir Tolmachev, Kalevi Kairemo, Hans Lundqvist, Mark Lubberink.   

Abstract

An important application of quantitative imaging in nuclear medicine is the estimation of absorbed doses in radionuclide therapy. Depending on the radionuclide used for therapy, quantitative imaging of the kinetics of the therapeutic radiopharmaceutical could be done using planar imaging, SPECT or PET. Since many nuclear medicine departments have a gamma camera system that is also suitable for coincidence imaging, the performance of these systems with respect to quantitative imaging of PET isotopes that could be of use in radionuclide dosimetry is of interest. We investigated the performance of a gamma camera with coincidence imaging capabilities with 99mTc, 111In, 18F and 76Br and a dedicated PET system with 18F and 76Br, using a single standard set of phantom measurements. Here, 76Br was taken as a typical example of prompt gamma-emitting PET isotopes that are applicable in radionuclide therapy dosimetry such as 86Y and 124I. Image quality measurements show comparable image contrasts for 76Br coincidence imaging and 111In SPECT. Although the spatial resolution of coincidence imaging is better than single photon imaging, the contrast obtained with 76Br is not better than that with 99mTc or 111In because of the prompt gamma involved. Additional improvements are necessary to allow for quantitative coincidence imaging of long-lived, prompt gamma producing positron emitters.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15724533     DOI: 10.1088/0031-9155/49/24/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry.

Authors:  Andrew P Robinson; Jill Tipping; David M Cullen; David Hamilton; Richard Brown; Alex Flynn; Christopher Oldfield; Emma Page; Emlyn Price; Andrew Smith; Richard Snee
Journal:  EJNMMI Phys       Date:  2016-07-13

Review 2.  Physics of pure and non-pure positron emitters for PET: a review and a discussion.

Authors:  Maurizio Conti; Lars Eriksson
Journal:  EJNMMI Phys       Date:  2016-05-23

Review 3.  Iodine-124: a promising positron emitter for organic PET chemistry.

Authors:  Lena Koehler; Katherine Gagnon; Steve McQuarrie; Frank Wuest
Journal:  Molecules       Date:  2010-04-13       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.