Literature DB >> 15723500

Ultrathin coatings from isocyanate-terminated star PEG prepolymers: layer formation and characterization.

Juergen Groll1, Thomas Ameringer, Joachim P Spatz, Martin Moeller.   

Abstract

In this study we present the preparation of thin and ultrathin coatings from six-arm star-shaped isocyanate-terminated prepolymers on amino-functionalized silicon wafers. The backbone of the stars is a statistical copolymer of ethylene oxide and propylene oxide in the ratio 80:20 (Star PEG). Film preparation by spin coating from aqueous THF resulted in a variety of film morphologies that are determined by the water content of the solvent. Water is indispensable for activation of the isocyanate-terminated stars in solution and for proper cross-linking of the coatings on the substrate. This cross-linking results in a dense network of PEG chains on the substrate linked via urea groups with a mesh size of the network that corresponds to the arm length of the stars. Layer thickness variations between 3 and 500 nm revealed a strong dependence of the contact angle with water on the layer thickness which is explained by the chemical composition of the coatings. Due to the high functionality of the star-shaped prepolymers, free amino groups remain in the films that were detected by fluorescence microscopy after reaction with 4-chloro-7-nitrobenzofurazan (NBF). To test the system for the ability to prevent unspecific interaction with proteins, adsorption of fluorescence-labeled avidin was examined with fluorescence microscopy. For layer thicknesses between 3 and 50 nm, no protein adsorption could be detected.

Entities:  

Year:  2005        PMID: 15723500     DOI: 10.1021/la047439f

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  5 in total

1.  Intraocular silicone implant to treat chronic ocular hypotony-preliminary feasibility data.

Authors:  Wesal Bayoudh; Markus Frentz; Dörthe Carstesen; Barbara Dittrich; Caroline Reismann; Norbert F Schrage; Peter Walter; Andreas W A Weinberger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-05-10       Impact factor: 3.117

2.  Surface-modified silicone foils for intraocular implantation.

Authors:  Sarah Fischer; Dörthe Carstesen; Doris Klee; Peter Walter; Andreas W A Weinberger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-23       Impact factor: 3.117

3.  Elastic Properties of Poly(ethylene glycol) Nanomembranes and Respective Implications.

Authors:  Zhiyong Zhao; Michael Zharnikov
Journal:  Membranes (Basel)       Date:  2022-05-10

4.  Intraocular silicone implant to treat chronic ocular hypotony: an in vivo trial.

Authors:  Wesal Bayoudh; Dörthe Carstesen; Peter Walter; Andreas W A Weinberger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-03       Impact factor: 3.117

5.  NCO-sP(EO-stat-PO) coatings on gold sensors--a QCM study of hemocompatibility.

Authors:  Stefan Sinn; Mirjam Eichler; Lothar Müller; Daniel Bünger; Jürgen Groll; Gerhard Ziemer; Frank Rupp; Hinnak Northoff; Jürgen Geis-Gerstorfer; Frank K Gehring; Hans P Wendel
Journal:  Sensors (Basel)       Date:  2011-05-13       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.