Literature DB >> 15723013

Primary stability of shoulder arthrodesis using cannulated cancellous screws.

Oliver Rühmann1, Ludger Kirsch, Sara Büch, Stephan Kirschner, Michael Bohnsack, Carl Joachim Wirth.   

Abstract

There are no biomechanical studies available concerned with the primary stability of shoulder arthrodesis. The aim of our biomechanical investigations was to ascertain a minimal material combination with high primary stability for shoulder arthrodesis. For that purpose, the primary stability of 6 different forms of screw arthrodesis was investigated under the stress of abduction, adduction, anteversion, and retroversion. The mean values of the screw arthrodeses were compared with those of a 16-hole plate arthrodesis. All tests were carried out on 24 human specimens without destruction by use of a materials testing machine. The most stable form of screw arthrodesis for the load directions of abduction, adduction, anteversion, and retroversion results from a specific configuration of screws comprising 3 horizontal humeroglenoid screws and 3 vertical acromiohumeral screws (318.5 +/- 99.0 N). For three forms of arthrodesis, each with 3 humerus-glenoid screws (299.9 +/- 95.4 N), no significant difference (P = .530) was found compared with a 16-hole plate arthrodesis (293.4 +/- 89.3 N). The plate arthrodeses only achieved higher power values on abduction and adduction stress in comparison with screw arthrodesis with 3 humerus-glenoid screws. The difference was insignificant. Because arthrodesis with 3 humerus-glenoid screws was significantly more stable on stress of anteversion and retroversion, this particular screw arthrodesis is considered superior to plate arthrodeses. The use of the most stable form of screw arthrodesis may reduce nonunion.

Entities:  

Mesh:

Year:  2005        PMID: 15723013     DOI: 10.1016/j.jse.2004.05.007

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  3 in total

Review 1.  [Shoulder arthrodesis. Indications, techniques, results, complications].

Authors:  O Rühmann; S Schmolke; M Bohnsack; L Kirsch; C J Wirth
Journal:  Orthopade       Date:  2004-09       Impact factor: 1.087

2.  [Arthrodesis of the shoulder. A new and soft-tissue-sparing technique with a deep locking plate in the supraspinatus fossa].

Authors:  A Klonz; P Habermeyer
Journal:  Unfallchirurg       Date:  2007-10       Impact factor: 1.000

3.  [Screw arthrodesis of the shoulder].

Authors:  S Lerch; T Berndt; W Lipka; O Rühmann
Journal:  Oper Orthop Traumatol       Date:  2011-07       Impact factor: 1.154

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.