Influence of image-capturing parameters on digital X-ray radiogrammetry.

Joachim Böttcher1, Alexander Pfeil, Anders Rosholm, Ansgar Malich, Alexander Petrovitch, Bianka Heinrich, Gabriele Lehmann, Hans-Joachim Mentzel, Gert Hein, Werner Linss, Werner A Kaiser.   

Abstract

The purpose of this study was to evaluate the importance of different image-capturing conditions, which might influence the characteristics of radiographs and, consequently, impact calculations of bone mineral density (BMD) and Metacarpal Index (MCI) using digital X-ray radiogrammetry (DXR). Radiographs of the left hand of deceased males were acquired three times using systematically varied parameters: 4-8 miliamp seconds (mA); 40-52 kV; film-focus distance (FFD); 90-130 cm; film sensitivity, 200/400; and different image modalities (conventional vs original digital radiographs as well as digital printouts). Furthermore, the interradiograph reproducibility using both conventional equipment and printouts vs originals of digital images and the intraradiograph reproducibility (either conventional or digital printouts) were evaluated. All BMD and MCI measurements were obtained with the DXR technology. The interradiograph reproducibility of DXR-BMD using conventional images under standardized conditions (6 mAs; 42 kV; 1 m FFD; film sensitivity of 200) was calculated to be coefficient of variation (CV) = 0.49% for Agfa Curix film and CV = 0.33% for Kodak T-MAT-Plus film, whereas reproducibility error using digital images ranged from CV = 0.57% (digital printouts; Philips) to CV = 1.50% (original digital images; Siemens). The intraradiograph reproducibility error was observed to be CV = 0.13% (conventional; Kodak film) vs CV = 0.27% (digital printouts; Philips). The BMD calculation was not noticeably affected by changes of FFD, exposure level, or film sensitivity/film brand, but was influenced by tube voltage (CV = 0.99% for Kodak film to CV = 2.05% for Siemens digital printouts). No significant differences were observed between the BMD and MCI data. DXR provides measurements of MCI and BMD with high precision and reproducibility. The measurements are unaffected by all tested image-capturing conditions, with the exception of tube voltage. In addition, different digital image devices clearly have an effect on DXR reproducibility.

Entities:  

Mesh:

Year:  2005        PMID: 15722592     DOI: 10.1385/jcd:8:1:087

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  16 in total

1.  Feasibility study of semi-automated measurements of finger joint space widths.

Authors:  Alexander Pfeil; Julia Sommerfeld; Rosemarie Fröber; Gabriele Lehmann; Ansgar Malich; Andreas Hansch; Gunter Wolf; Joachim Böttcher
Journal:  Rheumatol Int       Date:  2010-04-17       Impact factor: 2.631

2.  Computerized digital imaging techniques provided by digital X-ray radiogrammetry as new diagnostic tool in rheumatoid arthritis.

Authors:  Joachim Böttcher; Alexander Pfeil; Anders Rosholm; Max-Ludwig Schäfer; Ansgar Malich; Alexander Petrovitch; Bettina Seidl; Gabriele Lehmann; Hans-Joachim Mentzel; Gert Hein; Gunter Wolf; Werner A Kaiser
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

3.  Inhibition of periarticular bone loss is associated with clinical remission and ACR70-Response in rheumatoid arthritis.

Authors:  Alexander Pfeil; Anica Nussbaum; Diane M Renz; Christian Jung; Peter Oelzner; Ansgar Malich; Gunter Wolf; Joachim Böttcher
Journal:  Rheumatol Int       Date:  2018-12-19       Impact factor: 2.631

4.  Long-term in-vitro precision of direct digital X-ray radiogrammetry.

Authors:  Alvilde Dhainaut; Mari Hoff; Johan Kälvesten; Stian Lydersen; Kristina Forslind; Glenn Haugeberg
Journal:  Skeletal Radiol       Date:  2011-05-11       Impact factor: 2.199

5.  Influence of angulation on metacarpal bone mineral density measurements using digital X-ray radiogrammetry.

Authors:  Alexander Pfeil; Diane M Renz; Rosemarie Fröber; Andreas Hansch; Gabriele Lehmann; Julia Sommerfeld; Ansgar Malich; Gunter Wolf; Joachim Böttcher
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07-03       Impact factor: 2.924

6.  Reference values for digital X-ray radiogrammetry parameters in children and adolescents in comparison to estimates in patients with distal radius fractures.

Authors:  Diane M Renz; Ansgar Malich; Andreas Ulrich; Alexander Pfeil; Hans-Joachim Mentzel; Florian Streitparth; Martin H Maurer; Ulf K Teichgräber; Joachim Böttcher
Journal:  J Bone Miner Metab       Date:  2015-02-17       Impact factor: 2.626

7.  Age-related changes in cortical bone mass: data from a German female cohort.

Authors:  V A Molina Toledo; M Jergas
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

8.  Hand bone mineral density is associated with both total hip and lumbar spine bone mineral density in post-menopausal women with RA.

Authors:  Sonali P Desai; Ellen M Gravallese; Nancy A Shadick; Roberta Glass; Jing Cui; Michelle Frits; Lori B Chibnik; Nancy Maher; Michael E Weinblatt; Daniel H Solomon
Journal:  Rheumatology (Oxford)       Date:  2009-12-21       Impact factor: 7.580

9.  Digital X-ray radiogrammetry and its sensitivity and specificity for the identification of rheumatoid arthritis-related cortical hand bone loss.

Authors:  Alexander Pfeil; Glenn Haugeberg; Diane M Renz; Lisa Reinhardt; Christian Jung; Marcus Franz; Gunter Wolf; Joachim Böttcher
Journal:  J Bone Miner Metab       Date:  2016-03-15       Impact factor: 2.626

10.  Effects of leflunomide and methotrexate in rheumatoid arthritis detected by digital X-ray radiogrammetry and computer-aided joint space analysis.

Authors:  Alexander Pfeil; Julia Lippold; Thorsten Eidner; Gabriele Lehmann; Peter Oelzner; Diane M Renz; Andreas Hansch; Gunter Wolf; Gert Hein; Werner A Kaiser; Joachim Böttcher
Journal:  Rheumatol Int       Date:  2008-09-12       Impact factor: 2.631

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.