Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources.

J Pérez-Calatayud1, D Granero, E Casal, F Ballester, V Puchades.   

Abstract

In this study, complete dosimetric datasets for the CSM2 and CSM3 Cs-137 sources were obtained using the Monte Carlo GEANT4 code. The application of this calculation method was experimentally validated with thermoluminescent dosimetry (TLD). Functions and parameters following the TG43 formalism are presented: the dose rate constant, the radial dose functional, and the anisotropy function. In addition, to aid the quality control process on treatment planning systems, a two-dimensional (2D) rectangular dose rate table (the traditional along-away table), coherent with the TG43 dose calculation formalism, is given. The data given in this study complement existing information for both sources on the following aspects: (i) the source asymmetries were considered explicitly in the Monte Carlo calculations, (ii) TG43 data were derived directly from Monte Carlo calculations, (iii) the radial range of the different tables was increased as well as the angular resolution in the anisotropy function, including angles close to the longitudinal source axis. The CSM2 source TG-43 data of Liu et al. [Med. Phys. 31, 477-483 (2004)] are not consistent with the Williamson 2D along-away data [Int. J. Radiat. Oncol., Biol., Phys. 15, 227-237 (1988)] at distances closer than approximately 2 cm from the source. The data presented here for this source are consistent with this 2D along-away table, and are suitable for use in clinical practice.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15719951     DOI: 10.1118/1.1834835

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Monte Carlo-based investigation of water-equivalence of solid phantoms at (137)Cs energy.

Authors:  Ramkrushna S Vishwakarma; T Palani Selvam; Sridhar Sahoo; Subhalaxmi Mishra; Ghanshyam Chourasiya
Journal:  J Med Phys       Date:  2013-10

2.  Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources.

Authors:  Ma Carmen Pujades-Claumarchirant; Domingo Granero; Jose Perez-Calatayud; Facundo Ballester; Christopher Melhus; Mark Rivard
Journal:  J Contemp Brachytherapy       Date:  2010-04-01

3.  Establishment of air kerma reference standard for low dose rate Cs-137 brachytherapy sources.

Authors:  Sunil Dutt Sharma; Sudhir Kumar; P Srinivasan; G Chourasiya
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

4.  Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

Authors:  Luciana Tourinho Campos; Carlos Eduardo Veloso de Almeida
Journal:  PLoS One       Date:  2015-09-29       Impact factor: 3.240