Literature DB >> 15719187

Four- and eight-channel aortoiliac CT angiography: a comparative study.

Musturay Karcaaltincaba1, Dennis Foley.   

Abstract

PURPOSE: To compare performance parameters, contrast material load and radiation dose in a patient cohort having aortoiliac CT angiography using 4- and 8-channel multidetector CT (MDCT) systems.
METHODS: Eighteen patients with abdominal aortic aneurysms underwent initial 4-channel and follow-up 8-channel MDCT angiography. Both the 4- and 8-channel MDCT systems utilized a matrix detector of 16 x 1.25 mm rows. Scan coverage included the abdominal aorta and iliac arteries to the level of the proximal femoral arteries. For 4-channel MDCT, nominal slice thickness and beam pitch were 1.25 mm and 1.5, respectively, and for 8-channel MDCT they were 1.25 mm and 1.35 or 1.65 respectively. Scan duration, iodinated contrast material load and mean aortoiliac attenuation were compared retrospectively. Comparative radiation dose measurements for 4- and 8-channel MDCT were obtained using a multiple scan average dose technique on an abdominal phantom.
RESULTS: Compared with 4-channel MDCT, 8-channel MDCT aortoiliac angiography was performed with equivalent collimation, decreased contrast load (mean 45% decrease: 144 ml versus 83 ml of 300 mg iodine/ml contrast material) and decreased acquisition time (mean 51% shorter: 34.4 sec versus 16.9 sec) without a significant change in mean aortic enhancement (299 HU versus 300 HU, p > 0.05). Radiation dose was 2 rad for the 4-channel system and 2/1.5 rad for the 8-channel system at 1.35/1.65 pitch respectively.
CONCLUSION: Compared with 4-channel MDCT, aortoiliac CT angiography with 8-channel MDCT produces equivalent z-axis resolution with decreased contrast load and acquisition time without increased radiation exposure.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15719187     DOI: 10.1007/s00270-003-0131-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

Review 1.  Multidetector computed tomographic angiography of the cardiovascular system.

Authors:  Joshua Burrill; Zaid Dabbagh; Frank Gollub; Mohamed Hamady
Journal:  Postgrad Med J       Date:  2007-11       Impact factor: 2.401

Review 2.  Current status of contrast-induced nephropathy and nephrogenic systemic fibrosis in children.

Authors:  Musturay Karcaaltincaba; Berna Oguz; Mithat Haliloglu
Journal:  Pediatr Radiol       Date:  2009-06