Literature DB >> 15717156

Novel steerable telescoping catheter system for implantation of left ventricular pacing leads.

Jeffrey B Geske1, Robert N Goldstein, Bruce S Stambler.   

Abstract

Advances in left ventricular transvenous lead delivery systems for biventricular pacing are leading to more refined techniques, shorter procedure times and higher implant success rates. Despite these advances, the inability to successfully cannulate the coronary sinus and deliver a lead to a distal location are still major causes of prolonged procedures times and implant failures. The pathophysiologic process of heart failure results in dilatation of the right atrium as well as other morphological changes in cardiac anatomy. Additionally, cannulation can be further complicated by congenital anomalous cardiac anatomy. This report describes the implant of a biventricular pacing system using a novel, steerable 7 French catheter system developed to aid in the cannulation of the coronary sinus ostium and its venous branches. The steerable catheter is used in conjunction with a 9 French braided sheath and guide-wire to create a telescoping system. The use of new tools and methods as described provides insight into available options for left ventricular transvenous lead implantation and dealing with difficult anatomy.

Entities:  

Mesh:

Year:  2005        PMID: 15717156     DOI: 10.1007/s10840-005-5845-y

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  13 in total

1.  Cardiac resynchronization in chronic heart failure.

Authors:  William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger
Journal:  N Engl J Med       Date:  2002-06-13       Impact factor: 91.245

2.  A randomized comparison of alternative techniques to achieve coronary sinus cannulation during biventricular implantation procedures.

Authors:  Giuseppe De Martino; Tommaso Sanna; Antonio Dello Russo; Gemma Pelargonio; Loredana Messano; Carolina Ierardi; Daniele Gabrielli; Quintino Parisi; Paolo Zecchi; Fulvio Bellocci; Filippo Crea
Journal:  J Interv Card Electrophysiol       Date:  2004-06       Impact factor: 1.900

3.  Practical issues in cardiac resynchronization therapy device implantation.

Authors:  Angel R Leon
Journal:  Rev Cardiovasc Med       Date:  2003       Impact factor: 2.930

4.  A method for permanent transvenous left ventricular pacing.

Authors:  J J Blanc; D G Benditt; M Gilard; Y Etienne; J Mansourati; K G Lurie
Journal:  Pacing Clin Electrophysiol       Date:  1998-11       Impact factor: 1.976

5.  Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients.

Authors:  C Butter; A Auricchio; C Stellbrink; E Fleck; J Ding; Y Yu; E Huvelle; J Spinelli
Journal:  Circulation       Date:  2001-12-18       Impact factor: 29.690

6.  Transvenous left ventricular lead implantation with the EASYTRAK lead system: the European experience.

Authors:  H Pürerfellner; H J Nesser; S Winter; T Schwierz; H Hörnell; S Maertens
Journal:  Am J Cardiol       Date:  2000-11-02       Impact factor: 2.778

7.  QRS duration and mortality in patients with congestive heart failure.

Authors:  Stephen Iuliano; Susan G Fisher; Pamela E Karasik; Ross D Fletcher; Steven N Singh
Journal:  Am Heart J       Date:  2002-06       Impact factor: 4.749

8.  Functional abnormalities in isolated left bundle branch block. The effect of interventricular asynchrony.

Authors:  C L Grines; T M Bashore; H Boudoulas; S Olson; P Shafer; C F Wooley
Journal:  Circulation       Date:  1989-04       Impact factor: 29.690

9.  Effects of abnormal activation on the time course of the left ventricular pressure pulse in dilated cardiomyopathy.

Authors:  H B Xiao; S J Brecker; D G Gibson
Journal:  Br Heart J       Date:  1992-10

10.  Comparative prospective randomized efficacy testing of different guiding catheters for coronary sinus cannulation in heart failure patients.

Authors:  Christian Butter; Daniel Gras; Philippe Ritter; Christoph Stellbrink; Eckart Fleck; Bruce Tockman; Bernd Schubert; Thierry Pochet; Willem deVoogt
Journal:  J Interv Card Electrophysiol       Date:  2003-12       Impact factor: 1.900

View more
  4 in total

1.  [From guiding catheter to coronary sinus lead].

Authors:  H-H Minden; H Lehmann; J Meyhöfer; C Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006

2.  [Optimal electrode placement. What to consider during implantation of a biventricular pacemaker?].

Authors:  C Butter; H-H Minden
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-09

3.  The use of telescoping guide catheters for coronary sinus cannulation and sub-selecting tributaries in left ventricular lead placement.

Authors:  Jürgen Vogt; Torsten Schwarz; Daniel Gras; Johannes Sperzel; Philippe Ritter; Willem de Voogt; Jean-Pierre Cebron; Martin Seifert; Bruce Tockman; Bernd Schubert; Eric Johnson; Annette Doelger; Thierry Pochet; Elisabeth Mouton; Christian Butter
Journal:  J Interv Card Electrophysiol       Date:  2007-07-07       Impact factor: 1.900

4.  Implantation of cardiac resynchronization therapy devices using three leads by cephalic vein dissection approach.

Authors:  Alexios Hadjis; Riccardo Proietti; Vidal Essebag
Journal:  Europace       Date:  2017-09-01       Impact factor: 5.214

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.