| Literature DB >> 15716606 |
Abstract
The aim of this study was to identify the main factor affecting compliance and intima-media thickness of the elastic common carotid artery in continuous ambulatory peritoneal dialysis patients. Increased intima-media thickness and decreased arterial compliance are associated with elevated risk of cardiovascular disease. This study included 20 patients and 20 age- and sex- matched healthy control subjects. The compliance and intima-media thickness of the right common carotid artery within 1 cm to the bifurcation were measured three times using high-resolution B-mode echocardiography. Blood samples were obtained to measure levels of hemoglobin, phosphorus, total calcium, total CO2, serum albumin, C-reactive protein, serum total cholesterol, LDL- and HDL-cholesterol and triglycerides. We found that the compliance of common carotid artery was lower in the patient group than in the control group. In the patient group, the compliance of common carotid artery was positively correlated with serum albumin concentration, and intima-media thickness of common carotid artery was negatively correlated with serum albumin levels. Stepwise regression analysis showed that serum albumin concentration was independently related to the compliance of common carotid artery, suggesting hypoalbuminemia can independently give deleterious effects on the arterial wall in continuous ambulatory peritoneal dialysis patients.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15716606 PMCID: PMC2808580 DOI: 10.3346/jkms.2005.20.1.70
Source DB: PubMed Journal: J Korean Med Sci ISSN: 1011-8934 Impact factor: 2.153
Subject characteristics
Figures represent mean±S.D or median (range), *p<0.05 versus control group.
h-s CRP, high sensitivity C-reactive protein; Ca×P product, calcium×phosphorus product; LDL, low density lipoprotein; HDL, high density lipoprotein; PTH, parathyroid hormone.
Comparison of hemodynamic parameters in control and patient groups
Figures represent mean±S.D. *p<0.05 versus control group.
CCA-AC, common carotid artery-arterial compliance; CCA-IMT, common carotid artery-intima media thickness; LVM/BSA, left ventricular mass/body surface area; SBP, systolic blood pressure; DBP, diastolic blood pressure; MAP, mean arterial pressure; PP, pulse pressure; SV, stroke volume; EF, ejection fraction.
Fig. 1Correlation between common carotid artery compliance and serum albumin concentration.
CCA-AC, common carotid artery compliance.
Fig. 2Correlation between common carotid artery intima-media thickness and serum albumin concentration.
CCA-IMT, common carotid artery intima-media thickness.
Stepwise regression analysis with common carotid artery compliance as a dependent variable
R2=0.218, F=4.734.
Selected variables: age, sex, presence of diabetes mellitus, serum albumin concentration, high-sensitivity C-reactive protein level, serum total calcium and phosphorus concentrations, calcium×phosphorus product, Total/HDL cholesterol, LDL/HDL cholesterol, parathyroid hormone level, common carotid artery intima-media thickness, left ventricular mass index, systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse pressure and body mass index.