Literature DB >> 15714601

A high-throughput liquid chromatography/tandem mass spectrometry method for screening glutathione conjugates using exact mass neutral loss acquisition.

Jose Castro-Perez1, Robert Plumb, Li Liang, Eric Yang.   

Abstract

Chemically reactive metabolites may cause hepatotoxicity and as a result liver failure or other adverse side reactions. Therefore, this is a vital topic of interest because early reactive metabolite screening may prevent compound failure at a later stage. In order to address this issue, a screening assay has been developed to detect the formation of reactive metabolites by using glutathione as a trapping reagent, which will allow us to search for phase I metabolites and also glutathiones during in vitro metabolite screening using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with exact mass. Glutathione conjugations when fragmented by the mass spectrometer give a common loss corresponding to the pyroglutamic acid moiety, which can be monitored. Until recently, this work has been carried out with triple quadrupole technology using nominal mass. The advantage of the hybrid quadrupole time-of-flight mass spectrometer is the selectivity and sensitivity that can be achieved. Exact neutral loss detection is achieved via sequential low- and high-energy MS acquisitions. After detection of the loss of the pyroglutamic acid moiety, using a window of +/-20 mDa on the high-energy scan, MS/MS is carried out on the parent mass of interest to confirm the common neutral loss. Copyright 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15714601     DOI: 10.1002/rcm.1855

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  8 in total

1.  A novel high-capacity ion trap-quadrupole tandem mass spectrometer.

Authors:  Andrew N Krutchinsky; Herbert Cohen; Brian T Chait
Journal:  Int J Mass Spectrom       Date:  2007       Impact factor: 1.986

Review 2.  Drug metabolite profiling and identification by high-resolution mass spectrometry.

Authors:  Mingshe Zhu; Haiying Zhang; W Griffith Humphreys
Journal:  J Biol Chem       Date:  2011-06-01       Impact factor: 5.157

Review 3.  High-performance liquid chromatography-tandem mass spectrometry in the identification and determination of phase I and phase II drug metabolites.

Authors:  M Holcapek; L Kolárová; M Nobilis
Journal:  Anal Bioanal Chem       Date:  2008-03-15       Impact factor: 4.142

4.  A statistical procedure to selectively detect metabolite signals in LC-MS data based on using variable isotope ratios.

Authors:  Lung-Cheng Lin; Hsin-Yi Wu; Vincent Shin-Mu Tseng; Lien-Chin Chen; Yu-Chen Chang; Pao-Chi Liao
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-12       Impact factor: 3.109

5.  Nucleophile addition of reduced glutathione on 2-methyl-2-nitroso compound: a combined electron paramagnetic resonance spectroscopy and electrospray tandem mass spectrometry study.

Authors:  Mathilde Triquigneaux; Béatrice Tuccio; Robert Lauricella; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-07       Impact factor: 3.109

Review 6.  Analytical tools and approaches for metabolite identification in early drug discovery.

Authors:  Yuan Chen; Mario Monshouwer; William L Fitch
Journal:  Pharm Res       Date:  2006-10-18       Impact factor: 4.580

7.  Facilitated uptake of a bioactive metabolite of maritime pine bark extract (pycnogenol) into human erythrocytes.

Authors:  Max Kurlbaum; Melanie Mülek; Petra Högger
Journal:  PLoS One       Date:  2013-04-30       Impact factor: 3.240

Review 8.  DNA adductomics.

Authors:  Silvia Balbo; Robert J Turesky; Peter W Villalta
Journal:  Chem Res Toxicol       Date:  2014-02-25       Impact factor: 3.739

  8 in total