Literature DB >> 15714087

Multislice computed tomography-urography: intraindividual comparison of different preparation techniques for optimized depiction of the upper urinary tract in an animal model.

Joern Kemper1, Marc Regier, Philipp G C Begemann, Alexander Stork, Gerhard Adam, Claus Nolte-Ernsting.   

Abstract

OBJECTIVES: We sought to evaluate intraindividually 3 different preparation protocols for achieving improved opacification and anatomic depiction of the upper urinary tract in multisclice computed tomography urography (MSCTU) using a porcine model.
MATERIAL AND METHODS: MSCTU was performed in 8 healthy pigs. Each animal underwent 3 MSCT urographies using 3 different preparations before the injection of contrast material: A, intravenous (iv) saline (250 mL); B, iv low-dose furosemide (0.1 mg/kg); and C, iv saline (250 mL) plus iv low-dose furosemide (0.1 mg/kg). Image analysis was performed blinded to the applied protocols and included the evaluation of the opacification and anatomic depiction of the upper urinary tract by means of graded scales. Ureteral distension was determined and density was measured within the collecting system.
RESULTS: Furosemide significantly improved both mean opacification scores and mean scores of anatomic depiction compared with the exclusive infusion of saline for MSCTU. There was no significant difference between the application of furosemide and the combination of furosemide plus saline. A significant increase of 25-26% for ureteral distension was found when furosemide was applied. Significant lower mean attenuation values (Hounsfield units) and standard deviation were found within the opacified urine for diuretic-enhanced MSCTU.
CONCLUSIONS: Low-dose furosemide injection is superior to saline infusion for achieving optimal enhancement in MSCTU. It is not necessary to combine furosemide and saline infusion. In MSCTU, low-dose furosemide is a simple add-on simplifying image acquisition timing and removing the need for abdominal compression devices.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15714087     DOI: 10.1097/01.rli.0000153023.19104.b1

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  8 in total

Review 1.  [Multislice CT urography Aspects for technical management and clinical application].

Authors:  J Kemper; G Adam; C Nolte-Ernsting
Journal:  Radiologe       Date:  2005-10       Impact factor: 0.635

Review 2.  Understanding multislice CT urography techniques: Many roads lead to Rome.

Authors:  Claus Nolte-Ernsting; Nigel Cowan
Journal:  Eur Radiol       Date:  2006-09-05       Impact factor: 5.315

3.  CT urography: a comparison of strategies for upper urinary tract opacification.

Authors:  Rupan Sanyal; Amol Deshmukh; Virender Singh Sheorain; Kishor Taori
Journal:  Eur Radiol       Date:  2006-10-13       Impact factor: 5.315

4.  Three-dimensional CT pyelography for planning of percutaneous nephrostolithotomy: accuracy of stone measurement, stone depiction and pelvicalyceal reconstruction.

Authors:  Uday Patel; Richard Miles Walkden; Khurshid R Ghani; Ken Anson
Journal:  Eur Radiol       Date:  2009-01-14       Impact factor: 5.315

5.  Influence of bladder distension on opacification of urinary collecting system during CT urography.

Authors:  Josip Curić; Mirjana Vukelić-Marković; Petar Marusić; Ana Hrkać-Pustahija; Boris Brkljacić
Journal:  Eur Radiol       Date:  2008-02-15       Impact factor: 5.315

6.  CT urography: definition, indications and techniques. A guideline for clinical practice.

Authors:  Aart J Van Der Molen; Nigel C Cowan; Ullrich G Mueller-Lisse; Claus C A Nolte-Ernsting; Satoru Takahashi; Richard H Cohan
Journal:  Eur Radiol       Date:  2007-11-01       Impact factor: 5.315

7.  Multidetector CT urography: experimental analysis of radiation dose reduction in an animal model.

Authors:  Joern Kemper; Marc Regier; Paul M Bansmann; Philipp G C Begemann; Alexander Stork; Hans Dieter Nagel; Gerhard Adam; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-14       Impact factor: 5.315

Review 8.  Multidetector CT of the kidney.

Authors:  E M Coppenrath; U G Mueller-Lisse
Journal:  Eur Radiol       Date:  2006-03-28       Impact factor: 7.034

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.