Literature DB >> 15712717

Customized spectral band analysis compared with conventional Fourier analysis of heart rate variability in neonates.

N A M de Beer1, P Andriessen, R C M Berendsen, S G Oei, P F F Wijn, S Bambang Oetomo.   

Abstract

A customized filtering technique is introduced and compared with fast Fourier transformation (FFT) for analyzing heart rate variability (HRV) in neonates from short-term recordings. FFT is classically the most commonly used spectral technique to investigate cardiovascular fluctuations. FFT requires stability of the physiological signal within a 300 s time window that is usually analyzed in adults. Preterm infants, however, show characteristics of rapidly fluctuating heart rate and blood pressure due to an immature autonomic regulation, resulting in non-stationarity of these signals. Therefore neonatal studies use (half-overlapping or moving) windows of 64 s length within a recording time of 2-5 min. The proposed filtering technique performs a filtering operation in the frequency range of interest before calculating the spectrum, which allows it to perform an analysis of shorter periods of only 42 s. The frequency bands of interest are 0.04-0.15 Hz (low frequency, LF) and 0.4-1.5 Hz (high frequency, HF). Although conventional FFT analysis as well as the proposed alternative technique result in errors in the estimation of LF power, due to spectral leakage from the very low frequencies, FFT analysis is more sensitive to this effect. The response times show comparable behavior for both the techniques. Applying both the methods to heart rate data obtained from a neonate before and after atropine administration (inducing a wide range of HRV), shows a very significant correlation between the two methods in estimating LF and HF power. We conclude that a customized filtering technique might be beneficial for analyzing HRV in neonates because it reduces the necessary time window for signal stability.

Entities:  

Mesh:

Year:  2004        PMID: 15712717     DOI: 10.1088/0967-3334/25/6/004

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Fetal-growth-restricted preterm infants display compromised autonomic cardiovascular control on the first postnatal day but not during infancy.

Authors:  Emily Cohen; Flora Y Wong; Euan M Wallace; Joanne C Mockler; Alexsandria Odoi; Samantha Hollis; Rosemary S C Horne; Stephanie R Yiallourou
Journal:  Pediatr Res       Date:  2017-04-07       Impact factor: 3.756

2.  Influence of sympathetic activity in the control of peripheral microvascular tone in preterm infants.

Authors:  Celine Corbisier de Meautsart; Rebecca M Dyson; Joanna L Latter; Mary J Berry; Vicki L Clifton; Ian M R Wright
Journal:  Pediatr Res       Date:  2016-08-06       Impact factor: 3.756

3.  Kangaroo Care modifies preterm infant heart rate variability in response to heel stick pain: pilot study.

Authors:  Xiaomei Cong; Susan M Ludington-Hoe; Gail McCain; Pingfu Fu
Journal:  Early Hum Dev       Date:  2009-06-07       Impact factor: 2.079

4.  Autonomic nervous system function following prenatal opiate exposure.

Authors:  Matthew Todd Hambleton; Eric W Reynolds; Thitinart Sithisarn; Stuart J Traxel; Abhijit R Patwardhan; Timothy N Crawford; Marta S Mendiondo; Henrietta S Bada
Journal:  Front Pediatr       Date:  2013-10-17       Impact factor: 3.418

5.  Changes in heart rate variability in a premature infant with hydrocephalus.

Authors:  Zuzana Uhrikova; Branislav Kolarovszki; Kamil Javorka; Michal Javorka; Katarina Matasova; Hana Kolarovszka; Mirko Zibolen
Journal:  AJP Rep       Date:  2012-06-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.