Literature DB >> 15711849

Chemical-shift micro-imaging of subcutaneous lesions.

J Weis1, G Aström, B Vinnars, A Wanders, H Ahlström.   

Abstract

A chemical-shift imaging technique was used for the study of small subcutaneous lesions. This study concerns micro-imaging of two females suffering from a tenosynovial giant cell tumor and an epidermal cyst. High-resolution water, fat and chemical-shift artifact-free images were obtained on a whole-body MR unit (1.5 T) equipped with a 23-mm microscopy surface coil and standard gradients (23 mT/m). A significant improvement in signal-to-noise ratio was achieved by reducing the receiver bandwidth to values below +/-10 kHz. The image data sets were acquired with resolution 0.1 x 0.13 mm in the plane, slice thickness 0.5 mm and with acquisition time less than 3 min. Spatial resolution, fat suppression, image texture and edge delineation were improved on spectroscopic images compared with those on conventional MR images.

Entities:  

Mesh:

Year:  2005        PMID: 15711849     DOI: 10.1007/s10334-004-0099-8

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  8 in total

1.  High-resolution blood flow velocity measurements in the human finger.

Authors:  M Klarhöfer; B Csapo; C Balassy; J C Szeles; E Moser
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  In vivo MR micro imaging with conventional radiofrequency coils cooled to 77 degrees K.

Authors:  A C Wright; H K Song; F W Wehrli
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

3.  High-temperature superconducting surface coil for in vivo microimaging of the human skin.

Authors:  J C Ginefri; L Darrasse; P Crozat
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

4.  High-resolution spectroscopic imaging of the human skin.

Authors:  J Weis; A Ericsson; G Aström; P Szomolanyi; A Hemmingsson
Journal:  Magn Reson Imaging       Date:  2001-02       Impact factor: 2.546

5.  A high-temperature superconducting Helmholtz probe for microscopy at 9.4 T.

Authors:  S E Hurlston; W W Brey; S A Suddarth; G A Johnson
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

6.  In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis.

Authors:  H K Song; F W Wehrli
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

7.  In vivo MR microscopy of the human skin.

Authors:  H K Song; F W Wehrli; J Ma
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

8.  Chemical shift artifact-free microscopy: spectroscopic microimaging of the human skin.

Authors:  J Weis; A Ericsson; A Hemmingsson
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

  8 in total
  2 in total

1.  Clinical and experimental pancreatic islet transplantation to striated muscle: establishment of a vascular system similar to that in native islets.

Authors:  Gustaf Christoffersson; Johanna Henriksnäs; Lars Johansson; Charlotte Rolny; Håkan Ahlström; José Caballero-Corbalan; Ralf Segersvärd; Johan Permert; Olle Korsgren; Per-Ola Carlsson; Mia Phillipson
Journal:  Diabetes       Date:  2010-07-22       Impact factor: 9.461

2.  The incidence and diagnostic relevance of chemical shift artefact in the magnetic resonance imaging characterisation of superficial soft tissue masses.

Authors:  Asif Saifuddin; Shuaib Siddiqui; Ian Pressney; Michael Khoo
Journal:  Br J Radiol       Date:  2019-12-19       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.