Literature DB >> 15707794

Simultaneous EEG-fMRI acquisition: how far is it from being a standardized technique?

Girolamo Garreffa1, Marta Bianciardi, Gisela E Hagberg, Emiliano Macaluso, Maria Grazia Marciani, Bruno Maraviglia, Manuel Abbafati, Marco Carnì, Ivo Bruni, Luigi Bianchi.   

Abstract

Simultaneous EEG-fMRI is a powerful tool to study spontaneous and evoked brain activity because of the complementary advantages of the two techniques in terms of temporal and spatial resolution. In recent years, a significant number of scientific works have been published on this subject. However, many technical problems related to the intrinsic incompatibility of EEG and MRI methods are still not fully solved. Furthermore, simultaneous acquisition of EEG and event-related fMRI requires precise synchronization of all devices involved in the experimental setup. Thus, timing issue must be carefully considered in order to avoid significant methodological errors. The aim of the present work is to highlight and discuss some of technical and methodological open issues associated with the combined use of EEG and fMRI. These issues are presented in the context of preliminary data regarding simultaneous acquisition of event-related evoked potentials and BOLD images during a visual odd-ball paradigm.

Mesh:

Substances:

Year:  2004        PMID: 15707794     DOI: 10.1016/j.mri.2004.10.013

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Removal of movement artifact from high-density EEG recorded during walking and running.

Authors:  Joseph T Gwin; Klaus Gramann; Scott Makeig; Daniel P Ferris
Journal:  J Neurophysiol       Date:  2010-04-21       Impact factor: 2.714

2.  Reference-free removal of EEG-fMRI ballistocardiogram artifacts with harmonic regression.

Authors:  Pavitra Krishnaswamy; Giorgio Bonmassar; Catherine Poulsen; Eric T Pierce; Patrick L Purdon; Emery N Brown
Journal:  Neuroimage       Date:  2015-07-05       Impact factor: 6.556

3.  An open-source hardware and software system for acquisition and real-time processing of electrophysiology during high field MRI.

Authors:  Patrick L Purdon; Hernan Millan; Peter L Fuller; Giorgio Bonmassar
Journal:  J Neurosci Methods       Date:  2008-08-05       Impact factor: 2.390

4.  Removing Cardiac Artefacts in Magnetoencephalography with Resampled Moving Average Subtraction.

Authors:  Limin Sun; Seppo P Ahlfors; Hermann Hinrichs
Journal:  Brain Topogr       Date:  2016-08-08       Impact factor: 3.020

Review 5.  Present and future of simultaneous EEG-fMRI.

Authors:  Karin Rosenkranz; Louis Lemieux
Journal:  MAGMA       Date:  2010-01-26       Impact factor: 2.310

6.  Effects of Acute Nicotine Abstinence on Cue-elicited Ventral Striatum/Nucleus Accumbens Activation in Female Cigarette Smokers: A Functional Magnetic Resonance Imaging Study.

Authors:  Sean P David; Marcus R Munafò; Heidi Johansen-Berg; James Mackillop; Lawrence H Sweet; Ronald A Cohen; Raymond Niaura; Robert D Rogers; Paul M Matthews; Robert T Walton
Journal:  Brain Imaging Behav       Date:  2007-12       Impact factor: 3.978

7.  Contact Heat Evoked Potentials Using Simultaneous Eeg And Fmri And Their Correlation With Evoked Pain.

Authors:  Katherine Roberts; Anastasia Papadaki; Carla Gonçalves; Mary Tighe; Duncan Atherton; Ravikiran Shenoy; Donald McRobbie; Praveen Anand
Journal:  BMC Anesthesiol       Date:  2008-12-17       Impact factor: 2.217

8.  A modified oddball paradigm for investigation of neural correlates of attention: a simultaneous ERP-fMRI study.

Authors:  Mateusz Rusiniak; Monika Lewandowska; Tomasz Wolak; Agnieszka Pluta; Rafał Milner; Małgorzata Ganc; Andrzej Włodarczyk; Andrzej Senderski; Lech Sliwa; Henryk Skarżyński
Journal:  MAGMA       Date:  2013-03-17       Impact factor: 2.310

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.