Literature DB >> 15706978

Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish.

Lisa A Harrenstien1, Susan J Tornquist, Timothy J Miller-Morgan, Brian G Fodness, Kevin E Clifford.   

Abstract

OBJECTIVE: To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities.
DESIGN: Prospective study. ANIMALS: 41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). PROCEDURE: Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses.
RESULTS: Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. CONCLUSIONS AND CLINICAL RELEVANCE: Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.

Entities:  

Mesh:

Year:  2005        PMID: 15706978     DOI: 10.2460/javma.2005.226.255

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  14 in total

1.  Engineering a simple lateral flow device for animal blood coagulation monitoring.

Authors:  Hua Li; Daewoo Han; Giovanni M Pauletti; Andrew J Steckl
Journal:  Biomicrofluidics       Date:  2018-01-23       Impact factor: 2.800

2.  Lack of arterial PO2 downregulation in Atlantic salmon (Salmo salar L.) during long-term normoxia and hyperoxia.

Authors:  T Kristensen; B O Rosseland; A Kiessling; B Djordevic; J C Massabau
Journal:  Fish Physiol Biochem       Date:  2010-03-11       Impact factor: 2.794

3.  Blood biochemical status of deep-sea sharks following longline capture in the Gulf of Mexico.

Authors:  Bianca K Prohaska; Brendan S Talwar; R Dean Grubbs
Journal:  Conserv Physiol       Date:  2021-01-15       Impact factor: 3.079

4.  Effect of nutritional status and sampling intensity on recovery after dorsal aorta cannulation in free-swimming Atlantic salmon (Salmo salar L.).

Authors:  B Djordjevic; T Kristensen; Ø Øverli; B O Rosseland; A Kiessling
Journal:  Fish Physiol Biochem       Date:  2009-10-25       Impact factor: 2.794

5.  Evaluation of the i-STAT (portable clinical analyser) for measuring haematological parameters in Atlantic cod (Gadus morhua) at different CO2 and temperature conditions.

Authors:  Radoslav S Borissov; Sølvi Espeland; Martin H Iversen
Journal:  Fish Physiol Biochem       Date:  2019-10-03       Impact factor: 2.794

6.  Gene expression in Atlantic salmon skin in response to infection with the parasitic copepod Lepeophtheirus salmonis, cortisol implant, and their combination.

Authors:  Aleksei Krasnov; Stanko Skugor; Marijana Todorcevic; Kevin A Glover; Frank Nilsen
Journal:  BMC Genomics       Date:  2012-04-05       Impact factor: 3.969

7.  Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.

Authors:  Lauren J Stoot; Nicholas A Cairns; Felicia Cull; Jessica J Taylor; Jennifer D Jeffrey; Félix Morin; John W Mandelman; Timothy D Clark; Steven J Cooke
Journal:  Conserv Physiol       Date:  2014-04-04       Impact factor: 3.079

8.  Validation of the i-STAT and HemoCue systems for the analysis of blood parameters in the bar-headed goose, Anser indicus.

Authors:  T S Harter; M Reichert; C J Brauner; W K Milsom
Journal:  Conserv Physiol       Date:  2015-05-19       Impact factor: 3.079

9.  Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser.

Authors:  Matthew T Hamilton; John W Finger; Megan E Winzeler; Tracey D Tuberville
Journal:  Conserv Physiol       Date:  2016-01-08       Impact factor: 3.079

10.  Validation of the i-STAT system for the analysis of blood gases and acid-base status in juvenile sandbar shark (Carcharhinus plumbeus).

Authors:  T S Harter; P R Morrison; J W Mandelman; J L Rummer; A P Farrell; R W Brill; C J Brauner
Journal:  Conserv Physiol       Date:  2015-03-02       Impact factor: 3.079

View more