Literature DB >> 15704438

Iteration of transmit-beam aberration correction in medical ultrasound imaging.

Svein-Erik Måsøy1, Trond Varslot, Bjørn Angelsen.   

Abstract

Simulations of iterative transmit-beam aberration correction using a time-delay and amplitude filter have been performed to study the convergence of such a process. Aberration in medical ultrasonic imaging is usually modeled by arrival-time and amplitude fluctuations concentrated on the transducer array. This is an approximation of the physical aberration process, and may be applied to correct the transmitted signal using a time-delay and amplitude filter. Estimation of such a filter has proven difficult in the presence of severe aberration. Presented here is an iterative approach, whereby a filter estimate is applied to correct the transmit-beam. This beam induces acoustic backscatter better suited for arrival-time and amplitude estimation, thus facilitating an improved filter estimate. Two correlation-based methods for estimating arrival-time and amplitude fluctuations in received echoes from random scatterers were employed. Aberration was introduced using eight models emulating aberration produced by the human abdominal wall. Results show that only a few iterations are needed to obtain corrected transmit-beam profiles comparable to those of an ideal aberration correction filter. Furthermore, a previously developed focusing criterion is found to quantify the convergence accurately.

Entities:  

Mesh:

Year:  2005        PMID: 15704438     DOI: 10.1121/1.1823213

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  4 in total

1.  Shape-based ultrasound tomography using a Born model with application to high intensity focused ultrasound therapy.

Authors:  Başak Ulker Karbeyaz; Eric L Miller; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2008-05       Impact factor: 1.840

2.  Harmonic source wavefront aberration correction for ultrasound imaging.

Authors:  Scott W Dianis; Olaf T von Ramm
Journal:  J Acoust Soc Am       Date:  2011-01       Impact factor: 1.840

Review 3.  Spatial Coherence in Medical Ultrasound: A Review.

Authors:  James Long; Gregg Trahey; Nick Bottenus
Journal:  Ultrasound Med Biol       Date:  2022-03-11       Impact factor: 3.694

4.  A model of distributed phase aberration for deblurring phase estimated from scattering.

Authors:  Jason C Tillett; Jeffrey P Astheimer; Robert C Waag
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-01       Impact factor: 2.725

  4 in total