Literature DB >> 15701270

Intensity-modulated radiation therapy (IMRT) reduces the dose to the contralateral breast when compared to conventional tangential fields for primary breast irradiation: initial report.

Ajay K Bhatnagar1, Edward Brandner, Deborah Sonnik, Andrew Wu, Shalom Kalnicki, Melvin Deutsch, Dwight E Heron.   

Abstract

PURPOSE: This study was designed to compare the dose received by the contralateral breast during primary breast irradiation using intensity-modulated radiotherapy with the dose received via conventional tangential field techniques. METHODS/MATERIALS: Between March 2003 and March 2004, 44 patients with breast carcinoma were treated using 6-, 10-, or mixed 6/18-MV photons(36 with tangential intensity-modulated radiotherapy technique and eight with three-dimensional technique using tangential fields with wedges) for primary breast irradiation after breast-conserving surgery. Paired thermoluminescent dosimeters were placed on each patient's contralateral breast, 4 cm from the center of the medial border of the tangential field. The thermoluminescent dosimeters were left on the patient during a single fraction and then measured 24 hours later.
RESULTS: The mean dose delivered with photons to the primary breast for all patients was 4998 cGy [SD = 52], and the mean single fraction dose was 200 cGy [SD = 9]. The mean percent of the prescribed dose to the contralateral breast was 7.74% (SD = 2.35) for patients treated with intensity-modulated radiotherapy, compared with 9.74% [SD = 2.04] for the patients treated with conventional tangential field techniques. This represented a 20% reduction in the mean dose to the contralateral breast with the use of intensity-modulated radiotherapy when compared with the dose received via the three-dimensional technique, a result that was statistically significant.
CONCLUSION: Primary breast irradiation with tangential intensity-modulated radiotherapy technique significantly reduces the dose to the contralateral breast when compared with conventional tangential techniques.

Entities:  

Mesh:

Year:  2004        PMID: 15701270     DOI: 10.1097/00130404-200411000-00008

Source DB:  PubMed          Journal:  Cancer J        ISSN: 1528-9117            Impact factor:   3.360


  4 in total

1.  Assessment of contralateral mammary gland dose in the treatment of breast cancer using accelerated hypofractionated radiotherapy.

Authors:  Maria Tolia; Kalliopi Platoni; Andreas Foteineas; Maria-Aggeliki Kalogeridi; Anna Zygogianni; Nikolaos Tsoukalas; Mariangela Caimi; Niki Margari; Maria Dilvoi; Panagiotis Pantelakos; John Kouvaris; Vassilis Kouloulias
Journal:  World J Radiol       Date:  2011-09-28

2.  Comparison of dose distributions and organs at risk (OAR) doses in conventional tangential technique (CTT) and IMRT plans with different numbers of beam in left-sided breast cancer.

Authors:  Hande Bas Ayata; Metin Güden; Cemile Ceylan; Nadir Kücük; Kayihan Engin
Journal:  Rep Pract Oncol Radiother       Date:  2011-04-08

Review 3.  Radiation therapy planning with photons and protons for early and advanced breast cancer: an overview.

Authors:  Damien C Weber; Carmen Ares; Antony J Lomax; John M Kurtz
Journal:  Radiat Oncol       Date:  2006-07-20       Impact factor: 3.481

4.  The Survival Effect of Chest Wall With or Without Regional Lymphatic Radiotherapy for Breast Cancer Patients With T3~4N0M0.

Authors:  Guanqiao Li; Jia Yao; Junni Chen; Baizhen Cai; Xiangying Lin; Zetan Chen; Jiawei Chen; Han Wang; Shiping Yang
Journal:  Front Oncol       Date:  2021-07-12       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.