Literature DB >> 15700237

Characterisation of intact recombinant human erythropoietins applied in doping by means of planar gel electrophoretic techniques and matrix-assisted laser desorption/ionisation linear time-of-flight mass spectrometry.

Gerald Stübiger1, Martina Marchetti, Marietta Nagano, Christian Reichel, Günter Gmeiner, Günter Allmaier.   

Abstract

Our experiments show that it is possible to detect different types of recombinant human erythropoietins (rhEPOs), EPO-alpha, EPO-beta and novel erythropoesis stimulating protein (NESP), based on exact molecular weight (MW) determination by matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) applying a high-resolution time-of-flight (TOF) mass analyser in the linear mode. Detection limits for the highly purified, intact glycoproteins were achievable in the low fmol range (25-50 fmol) using a sample preparation method applying a hydrophobic sample support (DropStop) as MALDI target surface. These results are very promising for the development of highly sensitive detection methods for a direct identification of rhEPO after enrichment from human body fluids. During our investigation we were able to differentiate EPO-alpha, EPO-beta and NESP based on distinct molecular substructures at the protein level by specific enzymatic reactions. MW determination of the intact molecules by high resolving one-dimensional sodium dodecyl sulfate /polyacrylamide gel electrophoresis (1D SDS-PAGE) and isoform separation by planar isoelectric focusing (IEF) was compared with MALDI-MS data. Migration differences between the rhEPOs were observed from gel electrophoresis, whereby MWs of 38 kDa in the case of EPO-alpha/beta and 49 kDa for NESP could be estimated. In contrast, an exact MW determination by MALDI-MS based on internal calibration revealed average MWs of 29.8 +/- 0.3 kDa for EPO-alpha/beta and 36.8 +/- 0.4 kDa for NESP. IEF separation of the intact rhEPOs revealed the presence of four to eight distinct isoforms in EPO-alpha and EPO-beta, while four isoforms, which appeared in the more acidic area of the gels, were detected by immunostaining in NESP. A direct detection of the different N- or O-glycoform pattern from rhEPOs using MALDI-MS was possible by de-sialylation of the glycan structures and after de-N-glycosylation of the intact molecules. Thereby, the main glycoforms of EPO-alpha, EPO-beta and NESP could be characterised based on their N-glycan composition. A microheterogeneity of the molecules based on the degree of sialylation of the O-glycan was observable directly from the de-N-glycosylated protein.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15700237     DOI: 10.1002/rcm.1830

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  MUW researcher of the month.

Authors: 
Journal:  Wien Klin Wochenschr       Date:  2019-09       Impact factor: 1.704

2.  An HPLC-MALDI MS method for N-glycan analyses using smaller size samples: application to monitor glycan modulation by medium conditions.

Authors:  Michael P Gillmeister; Noboru Tomiya; Scott J Jacobia; Yuan C Lee; Stephen F Gorfien; Michael J Betenbaugh
Journal:  Glycoconj J       Date:  2009-12       Impact factor: 2.916

Review 3.  Proteoforms and their expanding role in laboratory medicine.

Authors:  Lauren M Forgrave; Meng Wang; David Yang; Mari L DeMarco
Journal:  Pract Lab Med       Date:  2021-11-27
  3 in total