Literature DB >> 15698737

'Low dose' 99mTc-Sestamibi for radioguided surgery of primary hyperparathyroidism.

D Rubello1, A Piotto, F Medi, M D Gross, B Shapiro, P Erba, G Mariani, M R Pelizzo.   

Abstract

AIM: In this study, we evaluated the efficacy of low dose (99m)Tc-Sestamibi administration for radioguided parathyroid surgery in patients with primary hyperparathyroidism (PHPT).
METHODS: Three hundred consecutive PHPT patients were studied between September, 1999 and July, 2003. Pre-operative work-up included (99m)Tc-pertechnetate/(99m)Tc-Sestamibi subtraction scintigraphy and high resolution ultrasonography (US). 37MBq of (99m)Tc-Sestamibi was injected i.v. in the operating suite approximately 10 min prior to the beginning of the surgical procedure for intraoperative radiolocalization; quick parathyroid hormone (QPTH) assays were performed.
RESULTS: Two hundred and seven of the 211 patients selected for minimally-invasive radioguided parathyroidectomy (MIRP) were successfully treated for a solitary parathyroid adenoma (PA) through a 2-2.5 cm skin incision (mean operative time 35 min, mean hospital stay 1.2 days). In the 89 patients selected for traditional bilateral neck exploration (BNE), radioguided surgery was not as successful in the identification of the PA, especially in patients with (99m)Tc-Sestamibi-avid thyroid nodules. Nevertheless, the combination of probe and QPTH measurement was very helpful in patients with multigland disease.
CONCLUSIONS: Low-dose (99m)Tc-Sestamibi administered few minutes before surgery is sufficient for MIRP in patients with high likelihood of a solitary PA and without concomitant (99m)Tc-Sestamibi-avid thyroid nodules. The combination of radioguided surgery and QPTH measurements is very useful in the early identification of unanticipated multigland disease.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15698737     DOI: 10.1016/j.ejso.2004.10.008

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  5 in total

1.  Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?

Authors:  Domenico Rubello; Giuliano Mariani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

2.  Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery.

Authors:  Domenico Rubello; Arianna Massaro; Silvia Cittadin; Lucia Rampin; Adil Al-Nahhas; Giuseppe Boni; Giuliano Mariani; Maria Rosa Pelizzo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-06-28       Impact factor: 9.236

3.  Radioguided parathyroidectomy effective in pediatric patients.

Authors:  Jocelyn F Burke; Kaitlin Jacobson; Ankush Gosain; Rebecca S Sippel; Herbert Chen
Journal:  J Surg Res       Date:  2013-06-14       Impact factor: 2.192

4.  Exposure of surgical staff in surgical probe applications in radioguided parathyroidectomy.

Authors:  Recep Bekiş; Pinar Celik; Banu Uysal; Mehmet Ali Koçdor; Koray Atila; Serdar Saydam; Omer Harmancioğlu; Hatice Durak
Journal:  Eur Arch Otorhinolaryngol       Date:  2008-06-10       Impact factor: 2.503

Review 5.  Use of (99m)Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature.

Authors:  Kristie A Denmeade; Chris Constable; Warren M Reed
Journal:  J Med Radiat Sci       Date:  2013-06-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.