Literature DB >> 1569869

Two-dimensional selective adiabatic pulses.

S Conolly1, J Pauly, D Nishimura, A Macovski.   

Abstract

Using the technique of separable k-space excitation, we have designed a two-dimensional selective adiabatic pulse that inverts magnetization from a square region in the xy plane with insensitivity to RF variations. We also have designed a two-dimensional adiabatic pulse that inverts selectively in frequency and in one spatial dimension. The pulses should be useful for both MR imaging and spectroscopy. We present experimental results to demonstrate that the two-dimensional adiabatic pulses are feasible on commercial MR imaging systems.

Mesh:

Year:  1992        PMID: 1569869     DOI: 10.1002/mrm.1910240211

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

Review 1.  Recent advances in magnetic resonance neurospectroscopy.

Authors:  Yael Rosen; Robert E Lenkinski
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

Review 2.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

3.  A semiadiabatic spectral-spatial spectroscopic imaging (SASSI) sequence for improved high-field MR spectroscopic imaging.

Authors:  Rebecca E Feldman; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

4.  A minimum-phase Shinnar-Le Roux spectral-spatial excitation RF pulse for simultaneous water and lipid suppression in 1H-MRSI of body extremities.

Authors:  Paul Kyu Han; Chao Ma; Kexin Deng; Shuang Hu; Kyung-Wook Jee; Kui Ying; Yen-Lin Chen; Georges El Fakhri
Journal:  Magn Reson Imaging       Date:  2017-09-14       Impact factor: 2.546

5.  High-resolution human cervical spinal cord imaging at 7 T.

Authors:  E E Sigmund; G A Suero; C Hu; K McGorty; D K Sodickson; G C Wiggins; J A Helpern
Journal:  NMR Biomed       Date:  2011-12-20       Impact factor: 4.044

6.  Designing 3D selective adiabatic radiofrequency pulses with single and parallel transmission.

Authors:  Albert Jang; Xiaoping Wu; Edward J Auerbach; Michael Garwood
Journal:  Magn Reson Med       Date:  2017-05-12       Impact factor: 4.668

Review 7.  Ultra-High-Field MR Neuroimaging.

Authors:  P Balchandani; T P Naidich
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

8.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

9.  Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for 1H MRSI at 7T.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

10.  Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery.

Authors:  Priti Balchandani; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.