Literature DB >> 1569488

Four radionuclide methods for left ventricular volume determination: comparison of a manual and an automated technique.

W C Levy1, M D Cerqueira, D T Matsuoka, G D Harp, F H Sheehan, J R Stratton.   

Abstract

This study compared the accuracy and reproducibility of three previously described and one new radionuclide method of measuring left ventricular volumes in 19 subjects using contrast ventriculographic volumes (n = 38, mean volume = 126.6 ml) as the gold standard. The four methods were compared using both manual and automated ROIs. For manual ROIs, the Links (189.7 ml, r = 0.85), Starling (183.2 ml, r = 0.77) and the new count ratio method (141.4 ml, r = 0.90) overestimated contrast volumes, while the Massardo method (122.5 ml, r = 0.91) provided accurate volumes. For the automated ROIs, we performed an interpolative background subtraction and used a 50% threshold of the highest count pixel to define the ventricular regions. The automated Massardo method severely underestimated the contrast volume (59.5 ml, r = 0.90), while the other automated methods yielded accurate volumes: Links (122.4 ml, r = 0.89), Starling (118.1 ml, r = 0.81) and the new count ratio method (125.0 ml, r = 0.90). The interobserver reproducibility of the automated methods was excellent (mean difference = 1%-4%) compared to the manual methods (2%-8%). Because no additional images, blood counting, attenuation, or decay correction were necessary, the manual Massardo method and the automated count ratio method are the simplest to perform. We conclude that automated determination of left ventricular volumes using the new count ratio method is rapid, accurate, reproducible and could readily be incorporated into routine clinical use.

Entities:  

Mesh:

Year:  1992        PMID: 1569488

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

2.  Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging.

Authors:  A E Iskandrian; G Germano; W VanDecker; J D Ogilby; N Wolf; R Mintz; D S Berman
Journal:  J Nucl Cardiol       Date:  1998 Nov-Dec       Impact factor: 5.952

3.  The effect of aging on phenylephrine response in normal subjects.

Authors:  Kenneth M Madden; Wayne C Levy; Arnold Jacobson; John R Stratton
Journal:  J Am Aging Assoc       Date:  2003-01

Review 4.  Noninvasive imaging of the heart and coronary arteries.

Authors:  Amy M West; Christopher M Kramer
Journal:  Surg Clin North Am       Date:  2009-08       Impact factor: 2.741

5.  Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions.

Authors:  Teresa Massardo; Rodrigo Jaimovich; Hugo Lavados; Daniela Gutiérrez; J Carlos Rodríguez; J Miguel Saavedra; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-20       Impact factor: 10.057

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.