Literature DB >> 1569483

Three-dimensional tumor dosimetry for hepatic yttrium-90-microsphere therapy.

P L Roberson1, R K Ten Haken, D L McShan, P E McKeever, W D Ensminger.   

Abstract

The nonuniformity of dose deposition for hepatic 90Y-microsphere therapy is believed to play an important role in the relative sparing of normal liver tissues. To help study this issue, three-dimensional dose calculations have been performed for the VX2 tumor model in the rabbit treated with hepatic arterial administration of 90Y-glass microspheres (90Y-MS). Colored, nonactivated spheres of similar size to 90Y-MS were injected into the hepatic artery to mimic the treatment deposition of 90Y-MS. Sample blocks of treated liver were serially sectioned (200 microns thickness), fixed and photographed showing the position of the colored microspheres. The microsphere positions were digitized into a three-dimensional treatment planning system, and three-dimensional dose calculations were performed. A 2-mm diameter liver tumor nodule receiving 15 times more microspheres than nearby normal liver resulted in tumor-to-normal-tissue (TNT) calculated dose ratios of 2.6 (average dose) and 1.9 (minimum dose). The nonuniform microsphere distribution resulted in a dose gradient over the nodule with a minimum value which was less than one half the average dose. The relative dose deposition in the vicinity of the tumor nodule does not fully reconcile the known liver tolerance dose derived from uniform irradiation with the large calculated average doses tolerated with this type of therapy.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1569483

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

Review 1.  SIRT of liver metastases: physiological and pathophysiological considerations.

Authors:  Christophe Van de Wiele; Alex Maes; Eddy Brugman; Yves D'Asseler; Bart De Spiegeleer; Gilles Mees; Karin Stellamans
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-07-17       Impact factor: 9.236

2.  Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours.

Authors:  S Ho; W Y Lau; T W Leung; M Chan; Y K Ngar; P J Johnson; A K Li
Journal:  Eur J Nucl Med       Date:  1996-08

3.  Biodistribution, Pharmacokinetics and Efficacy of 188Re(I)-Tricarbonyl-Labeled Human Serum Albumin Microspheres in an Orthotopic Hepatoma Rat Model.

Authors:  Liang-Cheng Chen; Wan-Chi Lee; Chung-Li Ho; Ya-Jen Chang; Su-Jung Chen; Chih-Hsien Chang
Journal:  In Vivo       Date:  2018 May-Jun       Impact factor: 2.155

4.  Heterogeneity of microsphere distribution in resected liver and tumour tissue following selective intrahepatic radiotherapy.

Authors:  Jonas Högberg; Magnus Rizell; Ragnar Hultborn; Johanna Svensson; Olof Henrikson; Johan Mölne; Peter Gjertsson; Peter Bernhardt
Journal:  EJNMMI Res       Date:  2014-09-16       Impact factor: 3.138

5.  Precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model.

Authors:  E Courtney Henry; Matthew Strugari; George Mawko; Kimberly Brewer; David Liu; Andrew C Gordon; Jeffrey N Bryan; Charles Maitz; Robert Abraham; S Cheenu Kappadath; Alasdair Syme
Journal:  EJNMMI Phys       Date:  2022-03-21

6.  Increased absorbed liver dose in Selective Internal Radiation Therapy (SIRT) correlates with increased sphere-cluster frequency and absorbed dose inhomogeneity.

Authors:  Jonas Högberg; Magnus Rizell; Ragnar Hultborn; Johanna Svensson; Olof Henrikson; Johan Mölne; Peter Gjertsson; Peter Bernhardt
Journal:  EJNMMI Phys       Date:  2015-04-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.