Literature DB >> 15694769

Assigning product ions from complex MS/MS spectra: the importance of mass uncertainty and resolving power.

Lekha Sleno1, Dietrich A Volmer, Alan G Marshall.   

Abstract

This study offers a unique insight into the mass accuracy and resolving power requirements in MS/MS analyses of complex product ion spectra. In the examples presented here, accurate mass assignments were often difficult because of multiple isobaric interferences and centroid mass shifts. The question then arose whether the resolving power of a medium-resolution quadrupole time-of flight (QqTOF) is sufficient or high-resolution Fourier-transform ion cyclotron resonance (FT-ICR) is required for unambiguous assignments of elemental compositions. For the comparison, two paralytic shellfish poisons (PSP), saxitoxin (STX) and neosaxitoxin (NEO), with molecular weights of 299 and 315 g x mol(-1), respectively, were chosen because of the high peak density in their MS/MS spectra. The assessment of QqTOF collision-induced dissociation spectra and FT-ICR infrared multiphoton dissociation spectra revealed that several intrinsic dissociation pathways leading to isobaric fragment ions could not be resolved with the QqTOF instrument and required FT-ICR to distinguish very close mass differences. The second major source of interferences was M + 1 species originating from coactivated 13C12Cc-1 ion contributions of the protonated molecules of the PSPs. The problem in QqTOF MS results from internal mass calibration when the MH+ ions of analyte and mass calibrant are activated at the same time in the collision or trapping cell. Although FT-ICR MS readily resolved these interfering species, the QqTOF did not provide resolving power >20,000 (full width at half maximum) required to separate most isobaric species. We were able to develop a semi-internal QqTOF calibration technique that activated only the isolated 12C isotope species of the protonated molecules, thus reducing the M + 1 interferences significantly. In terms of overall automated elemental formulas assignment, FT-ICR MS achieved the first formula hit for 100% of the product ions, whereas the QqTOF MS hit rate was only 56 and 65% for STX and NEO product ions, respectively. External mass calibration from commercial FT-ICR and QqTOF instruments gave similar results.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15694769     DOI: 10.1016/j.jasms.2004.10.001

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  28 in total

1.  Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept.

Authors:  C Eckers; J C Wolff; N J Haskins; A B Sage; K Giles; R Bateman
Journal:  Anal Chem       Date:  2000-08-15       Impact factor: 6.986

Review 2.  Metabolite identification in drug discovery.

Authors:  Alan P Watt; Russell J Mortishire-Smith; Ute Gerhard; Steven R Thomas
Journal:  Curr Opin Drug Discov Devel       Date:  2003-01

3.  Petroleomics: the next grand challenge for chemical analysis.

Authors:  Alan G Marshall; Ryan P Rodgers
Journal:  Acc Chem Res       Date:  2004-01       Impact factor: 22.384

4.  Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration.

Authors:  Bruce E Wilcox; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2002-11       Impact factor: 3.109

5.  Liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometric characterization of protein kinase C phosphorylation.

Authors:  Michael J Chalmers; John P Quinn; Greg T Blakney; Mark R Emmett; Harold Mischak; Simon J Gaskell; Alan G Marshall
Journal:  J Proteome Res       Date:  2003 Jul-Aug       Impact factor: 4.466

6.  Deconvolution of isobaric interferences in mass spectra.

Authors:  Juris Meija; Joseph A Caruso
Journal:  J Am Soc Mass Spectrom       Date:  2004-05       Impact factor: 3.109

7.  A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer.

Authors:  Maristella Colombo; Federico Riccardi Sirtori; Vincenzo Rizzo
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

8.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

9.  Identification of uncommon plant metabolites based on calculation of elemental compositions using gas chromatography and quadrupole mass spectrometry.

Authors:  O Fiehn; J Kopka; R N Trethewey; L Willmitzer
Journal:  Anal Chem       Date:  2000-08-01       Impact factor: 6.986

10.  Structural study of spirolide marine toxins by mass spectrometry. Part I. Fragmentation pathways of 13-desmethyl spirolide C by collision-induced dissociation and infrared multiphoton dissociation mass spectrometry.

Authors:  Lekha Sleno; Anthony J Windust; Dietrich A Volmer
Journal:  Anal Bioanal Chem       Date:  2003-11-28       Impact factor: 4.142

View more
  14 in total

1.  Intriguing differences in the gas-phase dissociation behavior of protonated and deprotonated gonyautoxin epimers.

Authors:  Felipe A Dörr; Borislav Kovačevi; Zvonimir B Maksi; Ernani Pinto; Dietrich A Volmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-16       Impact factor: 3.109

Review 2.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

3.  Post-acquisition data processing for the screening of transformation products of different organic contaminants. Two-year monitoring of river water using LC-ESI-QTOF-MS and GCxGC-EI-TOF-MS.

Authors:  S Herrera López; M M Ulaszewska; M D Hernando; M J Martínez Bueno; M J Gómez; A R Fernández-Alba
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-22       Impact factor: 4.223

4.  Evaluation of a high resolving power time-of-flight mass spectrometer for drug analysis in terms of resolving power and acquisition rate.

Authors:  Anna Pelander; Petra Decker; Carsten Baessmann; Ilkka Ojanperä
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-27       Impact factor: 3.109

5.  Structural Characterization of Carbohydrates by Fourier Transform Tandem Mass Spectrometry.

Authors:  Wen Zhou; Kristina Håkansson
Journal:  Curr Proteomics       Date:  2011-12-01       Impact factor: 0.837

Review 6.  Comparative mass spectrometry-based metabolomics strategies for the investigation of microbial secondary metabolites.

Authors:  Brett C Covington; John A McLean; Brian O Bachmann
Journal:  Nat Prod Rep       Date:  2017-01-04       Impact factor: 13.423

7.  Construction of confidence regions for isotopic abundance patterns in LC/MS data sets for rigorous determination of molecular formulas.

Authors:  Andreas Ipsen; Elizabeth J Want; Timothy M D Ebbels
Journal:  Anal Chem       Date:  2010-09-01       Impact factor: 6.986

8.  Biosynthetic intermediate analysis and functional homology reveal a saxitoxin gene cluster in cyanobacteria.

Authors:  Ralf Kellmann; Troco Kaan Mihali; Young Jae Jeon; Russell Pickford; Francesco Pomati; Brett A Neilan
Journal:  Appl Environ Microbiol       Date:  2008-05-16       Impact factor: 4.792

9.  Metabolic flux elucidation for large-scale models using 13C labeled isotopes.

Authors:  Patrick F Suthers; Anthony P Burgard; Madhukar S Dasika; Farnaz Nowroozi; Stephen Van Dien; Jay D Keasling; Costas D Maranas
Journal:  Metab Eng       Date:  2007-05-29       Impact factor: 9.783

10.  High-resolution extracted ion chromatography, a new tool for metabolomics and lipidomics using a second-generation orbitrap mass spectrometer.

Authors:  Albert Koulman; Gary Woffendin; Vinod K Narayana; Helen Welchman; Catharina Crone; Dietrich A Volmer
Journal:  Rapid Commun Mass Spectrom       Date:  2009-05       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.