BACKGROUND: We determined the reliability and repeatability of measurements of arterial compliance (AC) and gender- and age-specific normal ranges for a healthy European population. METHODS: Three hundred eight healthy volunteers from seven sites were evaluated. Two measurements were taken during the first visit, repeated on a second visit 1 to 4 weeks later. We used the HDI/PulseWave CR-2000 for measurements of AC. RESULTS: Intravisit measurements, taken 5 min apart, differed by less than 3% (range, 0.36% to 2.97%). All intervisit measures differed by less than 4% (range, 0.24% to 3.67%); none of these differences was statistically significant. All correlation coefficients for pairs of AC parameters measured 5 min apart at the same visit were significant at P < .0001. Paired AC parameters at visit 1 and 2 were highly correlated (P < .0001). Repeated measures GLM (general linear model) failed to detect a significant association between either of the AC parameters and visit (first or second), time (first or second measure at the same visit), and visit-by-time (the interaction of the two preceding factors), suggesting that order of measure had no effect on the final value. Analysis of reliability was used to develop a strictly parallel model estimate of unbiased reliability. Both intravisit and intervisit estimates of reliability indicate good repeatability of measure and were significant (P < .0001). The AC values were found to differ significantly by age group, with an inverse association between each of the AC parameters and age group. CONCLUSIONS: Measurement of the arterial waveform with the CR-2000 system is highly reproducible in healthy subjects.
BACKGROUND: We determined the reliability and repeatability of measurements of arterial compliance (AC) and gender- and age-specific normal ranges for a healthy European population. METHODS: Three hundred eight healthy volunteers from seven sites were evaluated. Two measurements were taken during the first visit, repeated on a second visit 1 to 4 weeks later. We used the HDI/PulseWave CR-2000 for measurements of AC. RESULTS: Intravisit measurements, taken 5 min apart, differed by less than 3% (range, 0.36% to 2.97%). All intervisit measures differed by less than 4% (range, 0.24% to 3.67%); none of these differences was statistically significant. All correlation coefficients for pairs of AC parameters measured 5 min apart at the same visit were significant at P < .0001. Paired AC parameters at visit 1 and 2 were highly correlated (P < .0001). Repeated measures GLM (general linear model) failed to detect a significant association between either of the AC parameters and visit (first or second), time (first or second measure at the same visit), and visit-by-time (the interaction of the two preceding factors), suggesting that order of measure had no effect on the final value. Analysis of reliability was used to develop a strictly parallel model estimate of unbiased reliability. Both intravisit and intervisit estimates of reliability indicate good repeatability of measure and were significant (P < .0001). The AC values were found to differ significantly by age group, with an inverse association between each of the AC parameters and age group. CONCLUSIONS: Measurement of the arterial waveform with the CR-2000 system is highly reproducible in healthy subjects.
Authors: Carmen A Peralta; David R Jacobs; Ronit Katz; Joachim H Ix; Magdalena Madero; Daniel A Duprez; Mark J Sarnak; Michael H Criqui; Holly J Kramer; Walter Palmas; David Herrington; Michael G Shlipak Journal: Am J Kidney Dis Date: 2011-10-14 Impact factor: 8.860
Authors: Margie E Jefferson; Barbara J Nicklas; Elizabeth A Chmelo; Charlotte I Crotts; Hossam A Shaltout; Debra I Diz; Anthony P Marsh; Tina E Brinkley Journal: Am J Hypertens Date: 2015-08-20 Impact factor: 2.689
Authors: Christopher A Fahs; Lindy M Rossow; Dong-Il Seo; Jeremy P Loenneke; Vanessa D Sherk; Eonho Kim; Debra A Bemben; Michael G Bemben Journal: Eur J Appl Physiol Date: 2011-03-29 Impact factor: 3.078
Authors: Carmen A Peralta; Kathryn L Adeney; Michael G Shlipak; David Jacobs; Daniel Duprez; David Bluemke; Joseph Polak; Bruce Psaty; Bryan R Kestenbaum Journal: Am J Epidemiol Date: 2009-11-30 Impact factor: 4.897
Authors: Daichi Shimbo; Steven Shea; Robyn L McClelland; Anthony J Viera; Devin Mann; Jonathan Newman; Joao Lima; Joseph F Polak; Bruce M Psaty; Paul Muntner Journal: Am J Hypertens Date: 2013-03-28 Impact factor: 2.689
Authors: Daniel A Duprez; David R Jacobs; Pamela L Lutsey; David Herrington; Darryl Prime; Pamela Ouyang; R Graham Barr; David A Bluemke Journal: Ethn Dis Date: 2009 Impact factor: 1.847