Literature DB >> 15691244

Prediction of patient discomfort during fibreoptic bronchoscopy.

Tadahiko Mitsumune1, Etsuo Senoh, Michifumi Adachi.   

Abstract

OBJECTIVE: This study investigated the potential for predicting which patients would have a negative emotional reaction to bronchoscopy.
METHODOLOGY: A questionnaire was distributed to 120 patients who had undergone diagnostic fibreoptic bronchoscopy. A visual analog scale to evaluate the patient's discomfort was adopted. Multiple linear regression analysis was used to determine factors significantly influencing discomfort. The regression model included the following variables: age, gender, symptoms, smoking habits, proximal bronchial brushing, distal bronchial brushing, bronchial washing, proximal transbronchial biopsy, transbronchial lung biopsy, examination time, the bronchoscopist's experience, and the patient's anxiety level.
RESULTS: The bronchoscopist's experience (P = 0.001) and the patient's anxiety level (P < 0.001) were variables that significantly influenced discomfort. These results suggest that discomfort decreased with the bronchoscopist's experience and increased with the patient's anxiety regarding bronchoscopy.
CONCLUSIONS: The results suggest that subjective discomfort can be predicted both by the bronchoscopist's experience and by a questionnaire about the patient's anxiety level before bronchoscopy. Therefore, it is recommended that the patient's anxiety level be determined through the use of a questionnaire before bronchoscopy, and that more experienced bronchoscopists should take charge if the patient is judged as being excessively anxious. If experienced bronchoscopists are unavailable, the more anxious patient should receive more sedatives.

Entities:  

Mesh:

Year:  2005        PMID: 15691244     DOI: 10.1111/j.1440-1843.2005.00642.x

Source DB:  PubMed          Journal:  Respirology        ISSN: 1323-7799            Impact factor:   6.424


  6 in total

Review 1.  Complications and discomfort of bronchoscopy: a systematic review.

Authors:  Elise Orvedal Leiten; Einar Marius Hjellestad Martinsen; Per Sigvald Bakke; Tomas Mikal Lind Eagan; Rune Grønseth
Journal:  Eur Clin Respir J       Date:  2016-11-11

2.  Novel predictive factors for patient discomfort and severe cough during bronchoscopy: A prospective questionnaire analysis.

Authors:  Fumi Kobayashi; Takeshi Saraya; Miku Oda; Sho Sakuma; Masato Watanabe; Saori Takata; Masaki Tamura; Hiroki Takakura; Keitaro Nakamoto; Kojiro Honda; Kosuke Ohkuma; Sunao Mikura; Manami Inoue; Aya Hirata; Nozomi Kurokawa; Tatsuya Shirai; Kaori Aso; Akinari Noda; Chika Miyaoka; Yuki Yoshida; Narishige Ishikawa; Kikuko Morita; Eriko Ieki; Hiromi Nakajima; Haruyuki Ishii; Hajime Takizawa
Journal:  PLoS One       Date:  2020-10-19       Impact factor: 3.240

3.  Effect of Bronchoscopist-Directed Sedation and Other Factors on Patient Comfort during Diagnostic Flexible Bronchoscopy.

Authors:  Rahul Magazine; Keerthi Nedumala Sisupalan; Vyshak Uddur Surendra; Bharti Chogtu; Preetam Rajgopal Acharya; Vasudeva Guddattu
Journal:  Scientifica (Cairo)       Date:  2022-01-21

4.  A Prospective Observational Study on the Tolerability of Transnasal Bronchoscopy With a Surgical Mask for Aerosol Control.

Authors:  Yusuke Usui; Shinji Sasada; Keisuke Kirita; Sayaka Nagayama; Saori Murata; Yumi Tsuchiya; Kota Ishioka; Saeko Takahashi; Morio Nakamura; Kazuma Kishi
Journal:  Cureus       Date:  2022-08-20

5.  Evaluation of patients' satisfaction with bronchoscopy procedure.

Authors:  Aleksandra Karewicz; Katarzyna Faber; Katarzyna Karon; Katarzyna Januszewska; Joanna Ryl; Piotr Korczynski; Katarzyna Gorska; Marta Dabrowska; Rafal Krenke
Journal:  PLoS One       Date:  2022-10-06       Impact factor: 3.752

6.  Factors affecting patients' comfort during fiberoptic bronchoscopy and endobronchial ultrasound.

Authors:  Fatma Yıldırım; Şevket Özkaya; Ahmet Selim Yurdakul
Journal:  J Pain Res       Date:  2017-03-29       Impact factor: 3.133

  6 in total