Literature DB >> 15690524

Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque.

Christian T Farrar1, Van J Wedeen, Jerome L Ackerman.   

Abstract

In order to improve the performance of magnetic resonance imaging and spectroscopy of atherosclerotic plaque the potential use of novel radiofrequency coil structures with sensitive detection volumes tailored to the geometry of the arterial wall was investigated. It was found that a cylindrical meanderline (zig-zag) coil design provides a sensitive volume that is restricted to a cylindrical shell, thereby maximizing the filling factor and signal-to-noise ratio for plaques while reducing the intense blood signal. The cylindrical meanderline coil has the added advantages of an open interior, which allows for unimpeded blood flow during scanning, and the potential to be expanded against the walls of the artery, thereby stabilizing the coil against the pulsatile blood flow and minimizing motion artifacts. The performance of cylindrical meanderline coils with theoretical simulations of the electromagnetic fields as well as with experimental images of test objects (phantoms) and human endarterectomy surgical specimens is demonstrated. This radically new RF coil geometry offers the potential to improve the efficiency of MR data acquisition in medical applications in which curved surfaces or slabs contain the material of interest. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15690524     DOI: 10.1002/mrm.20330

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

Review 1.  Imaging techniques for the vulnerable coronary plaque.

Authors:  F Cademartiri; L La Grutta; A Palumbo; E Maffei; A Aldrovandi; R Malagò; F Alberghina; F Pugliese; G Runza; M Belgrano; M Midiri; M A Cova; G P Krestin
Journal:  Radiol Med       Date:  2007-07-24       Impact factor: 3.469

2.  Modeling Endovascular MRI Coil Coupling With Transmit RF Excitation.

Authors:  Madhav Venkateswaran; Orhan Unal; Samuel Hurley; Alexey Samsonov; Peng Wang; Sean B Fain; Krishna N Kurpad
Journal:  IEEE Trans Biomed Eng       Date:  2016-03-04       Impact factor: 4.538

3.  The misunderstood meander: Redesigning MRI meander-line surface coils to reduce noise, increase uniformity, and eliminate image artifacts.

Authors:  Gary Zabow; Stephen Dodd; Alan Koretsky
Journal:  J Magn Reson       Date:  2021-10-30       Impact factor: 2.734

4.  Surgically implantable magnetic resonance angiography coils improve resolution to allow visualization of blood flow dynamics.

Authors:  Tamara N Fitzgerald; Akihito Muto; Tiffany T Fancher; Peter B Brown; Karen A Martin; Bart E Muhs; Douglas L Rothman; R Todd Constable; Smita Sampath; Alan Dardik
Journal:  Ann Vasc Surg       Date:  2009-12-29       Impact factor: 1.466

Review 5.  Acquired diseases of the thoracic aorta: role of MRI and MRA.

Authors:  Vincenzo Russo; Matteo Renzulli; Katia Buttazzi; Rossella Fattori
Journal:  Eur Radiol       Date:  2005-10-13       Impact factor: 7.034

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.