Literature DB >> 15688722

Retentive force and microleakage of stainless steel crowns cemented with three different luting agents.

Yucel Yilmaz1, Anya Dalmis, Taskin Gurbuz, Sera Simsek.   

Abstract

The aim of this investigation was to compare the tensile strength, microleakage, and Scanning Electron Microscope (SEM) evaluations of SSCs cemented using different adhesive cements on primary molars. Sixty-three extracted primary first molars were used. Tooth preparations were done. Crowns were altered and adapted for investigation purpose, and then cemented using glass ionomer cement (Aqua Meron), resin modified cement (RelyX Luting), and resin cement (Panavia F) on the prepared teeth. Samples were divided into two groups of 30 samples each for tensile strength and microleakage tests. The remaining three samples were used for SEM evaluation. Data were analyzed with one-way ANOVA and Tukey test. The statistical analysis of ANOVA revealed significant differences among the groups for both tensile strength and microleakage tests (p < 0.05). Tukey test showed statistically significant difference between Panavia F and RelyX Luting (p < 0.05), but none between the others (p > 0.05). This study showed that the higher the retentive force a crown possessed, the lower would be the possibility of microleakage.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15688722     DOI: 10.4012/dmj.23.577

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  8 in total

1.  In vitro comparison of microleakge between preformed metal crowns and aesthetic crowns of primary molars using different adhesive luting cements.

Authors:  S N Al-Haj Ali; R I Farah
Journal:  Eur Arch Paediatr Dent       Date:  2018-10-02

Review 2.  In vitro Evaluation of Stainless Steel Crowns cemented with Resin-modified Glass Ionomer and Two New Self-adhesive Resin Cements.

Authors:  Sidhant Pathak; K K Shashibhushan; P Poornima; Vv Subba Reddy
Journal:  Int J Clin Pediatr Dent       Date:  2016-09-27

3.  Effects of Hybrid Coat on shear bond strength of five cements: an in vitro study.

Authors:  Yue Guo; Hou-De Zhou; Yun-Zhi Feng
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

4.  Evaluation of retentive strength of four luting cements with stainless steel crowns in primary molars: An in vitro study.

Authors:  Iman Parisay; Yegane Khazaei
Journal:  Dent Res J (Isfahan)       Date:  2018 May-Jun

5.  Comparison of Microleakage of Pedo Jacket Crowns and Stainless Steel Crowns Cemented with Different Cements.

Authors:  Mona Sohrabi; Sara Ghadimi; Bahman Seraj
Journal:  Front Dent       Date:  2019-01-20

6.  Bond strength and microleakage of different types of cements in stainless steel crown of primary molar teeth.

Authors:  Somayeh Kameli; Fatemeh Khani; Marjan Bahraminasab; Raheb Ghorbani; Fatemeh Mashhadi Abbas
Journal:  Dent Res J (Isfahan)       Date:  2021-07-19

7.  Clinical Evaluation of Pediatric Posterior Zirconia and Stainless Steel Crowns: A Comparative Study.

Authors:  Gayathri Murali; Jayanthi Mungara; Poornima Vijayakumar; Keerthi T; Sai Sarath Kumar Kothimbakkam; Santhosh Priya Akr
Journal:  Int J Clin Pediatr Dent       Date:  2022 Jan-Feb

8.  In vitro comparison of microleakage with two different techniques of placing stainless steel crowns on mandibular deciduous first molar teeth with decreased mesiodistal width.

Authors:  Mahsa Sayadizadeh; Raziyeh Shojaeipour; Hamidreza Poureslami; Sajad Raeisi Estabragh; Maryam Sharifi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2022-05-29
  8 in total