Literature DB >> 15685686

The combination of liquid chromatography/tandem mass spectrometry and chip-based infusion for improved screening and characterization of drug metabolites.

Roland F Staack1, Emmanuel Varesio, Gérard Hopfgartner.   

Abstract

An approach has been developed for drug metabolism studies of non-radiolabeled compounds using on-line liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with chip-based infusion following fraction collection. The potential of this approach, which improves the data quality compared with only LC/MS analysis, has been investigated for the analysis of in vitro metabolites of tolcapone and talinolol, two compounds with well-characterized metabolism. The information-dependent LC/MS/MS analysis enables the characterization of the major metabolites while the chip-based infusion is used to obtain good product ion spectra for lower level metabolites, to generate complementary MS information on potential metabolites detected in the LC/MS trace, or to screen for unexpected metabolites. Fractions from the chromatographic analysis are collected in 20 second steps, into a 96-well plate. The fractions of interest can be re-analyzed with chip-based infusion on a variety of mass spectrometers including triple quadrupole linear ion trap (QqLIT or Q TRAP) and QqTOF systems. Acquiring data for several minutes using multi-channel acquisition (MCA), or signal averaging while infusing the fractions at approximately 200 nL/min, permits about a 50 times gain in sensitivity (signal-to-noise) in MS/MS mode. A 5-10 microL sample fraction can be infused for more than 30 min allowing the time to perform various MS experiments such as MS(n), precursor ion or neutral loss scans and accurate mass measurement, all in either positive or negative mode. Through fraction collection and infusion, a significant gain in data quality is obtained along with a time-saving benefit, because the original sample needs neither to be re-analyzed by re-injection nor to be pre-concentrated. Therefore, a novel hydroxylated talinolol metabolite could be characterized with only one injection.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15685686     DOI: 10.1002/rcm.1829

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

Review 1.  High-performance liquid chromatography-tandem mass spectrometry in the identification and determination of phase I and phase II drug metabolites.

Authors:  M Holcapek; L Kolárová; M Nobilis
Journal:  Anal Bioanal Chem       Date:  2008-03-15       Impact factor: 4.142

Review 2.  Mass spectrometry techniques in the survey of steroid metabolites as potential disease biomarkers: a review.

Authors:  Maria João Gouveia; Paul J Brindley; Lúcio Lara Santos; José Manuel Correia da Costa; Paula Gomes; Nuno Vale
Journal:  Metabolism       Date:  2013-05-07       Impact factor: 8.694

Review 3.  Analytical tools and approaches for metabolite identification in early drug discovery.

Authors:  Yuan Chen; Mario Monshouwer; William L Fitch
Journal:  Pharm Res       Date:  2006-10-18       Impact factor: 4.580

4.  Towards high-throughput metabolomics using ultrahigh-field Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Jun Han; Ryan M Danell; Jayanti R Patel; Dmitry R Gumerov; Cameron O Scarlett; J Paul Speir; Carol E Parker; Ivan Rusyn; Steven Zeisel; Christoph H Borchers
Journal:  Metabolomics       Date:  2008-06       Impact factor: 4.290

5.  A novel chromatographic method allows on-line reanalysis of the proteome.

Authors:  Leonie F Waanders; Reinaldo Almeida; Simon Prosser; Jürgen Cox; Daniel Eikel; Mark H Allen; Gary A Schultz; Matthias Mann
Journal:  Mol Cell Proteomics       Date:  2008-04-29       Impact factor: 5.911

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.