Literature DB >> 15683513

Bifocal right ventricular cardiac resynchronization therapies in patients with unsuccessful percutaneous lateral left ventricular venous access.

D O'Donnell1, V Nadurata, A Hamer, P Kertes, U Mohamed, W Mohammed.   

Abstract

Biventricular cardiac resynchronization therapy (CRT) with a lateral left ventricular (LV) lead cannot always be achieved. We report a single center experience of CRT utilizing a protocol that specifically required the implantation of a bifocal right ventricular (RV) lead system when lateral LV pacing could not be achieved. Consecutive candidates for CRT were included in the study. If strict criteria for lateral LV pacing were not met, they underwent implantation of a bifocal RV lead system with two 7F, active fixation leads, one placed septally at the apex, and the other in the high septal outflow tract. All patients were followed for 12 months and the two groups were compared. A biventricular (BiV) stimulation system was implanted in 44 patients, and a bifocal RV system in six. The demographic characteristics of the two groups were similar. Both groups experienced a similar improvement in functional capacity, increase in 6 minutes walking distance, and decreased need for hospitalizations. The mean increase in LV ejection fraction was 11% in the bifocal RV group versus 10% in the BiV group. Though the tissue Doppler indices of LV synchrony improved earlier in the BiV group, (19% vs 10%) the improvement was similar in both groups at 6 months (23% vs 20%). The clinical improvements conferred by CRT can be matched by a bifocal RV system in selected patients. This alternate approach should be considered when implantation of a LV lateral lead was unsuccessful.

Entities:  

Mesh:

Year:  2005        PMID: 15683513     DOI: 10.1111/j.1540-8159.2005.00069.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

Review 1.  How to improve outcomes with cardiac resynchronisation therapy: importance of lead positioning.

Authors:  Peter J Cowburn; Christophe Leclercq
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

Review 2.  [His-bundle stimulation and alternative RV stimulation sites].

Authors:  G Fröhlig; M Kindermann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-03

3.  Bifocal right ventricular pacing: an alternative way to achieve resynchronization when left ventricular lead insertion is unsuccessful.

Authors:  Skevos Sideris; Constantina Aggeli; Emmanouil Poulidakis; Kostas Gatzoulis; Ioannis Vlaseros; Katerina Avgeropoulou; Ioannis Felekos; Ilias Sotiropoulos; Christodoulos Stefanadis; Ioannis Kallikazaros
Journal:  J Interv Card Electrophysiol       Date:  2012-05-03       Impact factor: 1.900

Review 4.  Controversies in pacing: indications and programming.

Authors:  Anne M Gillis; Rik Willems
Journal:  Curr Cardiol Rep       Date:  2005-09       Impact factor: 2.931

5.  A streamlined technique of trans-septal endocardial left ventricular lead placement.

Authors:  Ernest W Lau
Journal:  J Interv Card Electrophysiol       Date:  2009-04-22       Impact factor: 1.900

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.