Literature DB >> 15683509

Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients.

Laurent Fauchier1, Nicolas Sadoul, Claude Kouakam, Florent Briand, Michel Chauvin, Dominique Babuty, Jacques Clementy.   

Abstract

Home monitoring (HM) of cardioverter defibrillators (ICD) with its automated wireless remote data access, may decrease the rate of patient visits. This study examined the potential cost savings for the long-term care of ICD assisted by HM. A French database including 502 patients from 6 university hospitals was used. Costs of conventional follow-up (FU) of ICD were calculated without, and compared with the expected cost of FU with HM. Calculations included number of visits, including physician's fees, electrocardiograms, and specific ICD surveillance, and transportation costs. The mean distance between home and institutions performing follow-ups was 69 +/- 57 km. For each visit, a mean overall cost of 215 dollars was calculated, including 121 dollars for transportation and 94 dollars for medical services. HM may obviate up to 2 visits per year. Over the 5 years of expected life of the device, the decrease in costs for FU visits was estimated at 2,149 dollars. With an additional cost of 1,200 dollars for the HM system, saving began after a mean FU of 33.5 months. The time to onset of cost saving by HM ranged between 17.4 months for patients living >150 km from the medical facility to 52.2 months for those living <50 km away. It is concluded that the HM may considerably reduce the overall costs of ICD FU by saving on transportation cost, particularly when the distance between home and medical facility is >100 km.

Entities:  

Mesh:

Year:  2005        PMID: 15683509     DOI: 10.1111/j.1540-8159.2005.00071.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  29 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  Workload, time and costs of the informal cares in patients with tele-monitoring of pacemakers: the PONIENTE study.

Authors:  Antonio López-Villegas; Daniel Catalán-Matamoros; Emilio Robles-Musso; Salvador Peiró
Journal:  Clin Res Cardiol       Date:  2015-09-30       Impact factor: 5.460

3.  [Home monitoring of an incessant VT in an ICD patient].

Authors:  N Reinsch; D Woydowski; H Schön; M Buddensiek; W Weissenberger; R Erbel; T Konorza
Journal:  Herz       Date:  2010-12-23       Impact factor: 1.443

4.  Use of "IEGM Online" in ICD patients--early detection of inappropriate classified ventricular tachycardia via home monitoring.

Authors:  Oliver Ritter; Wolfgang R Bauer
Journal:  Clin Res Cardiol       Date:  2006-06-20       Impact factor: 5.460

Review 5.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

6.  Remote monitoring of implanted cardiac devices: a plea for a nationwide exploration.

Authors:  N M van Hemel
Journal:  Neth Heart J       Date:  2009-11       Impact factor: 2.380

7.  Current practices in the monitoring of cardiac rhythm devices in pediatrics and congenital heart disease.

Authors:  Stacey L Boyer; Michael J Silka; Yaniv Bar-Cohen
Journal:  Pediatr Cardiol       Date:  2014-12-20       Impact factor: 1.655

Review 8.  Home Monitoring: what can we expect in the future?

Authors:  J-C Deharo; P Djiane
Journal:  Clin Res Cardiol       Date:  2006       Impact factor: 5.460

Review 9.  Remote monitoring of cardiac implantable electronic devices (CIED).

Authors:  Emily P Zeitler; Jonathan P Piccini
Journal:  Trends Cardiovasc Med       Date:  2016-03-31       Impact factor: 6.677

10.  Design of the evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study to assess the ability of remote monitoring to treat and triage patients more effectively.

Authors:  Maurizio Marzegalli; Maurizio Landolina; Maurizio Lunati; Giovanni B Perego; Alessia Pappone; Giuseppe Guenzati; Carlo Campana; Maria Frigerio; Gianfranco Parati; Antonio Curnis; Irene Colangelo; Sergio Valsecchi
Journal:  Trials       Date:  2009-06-18       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.