Literature DB >> 15683480

Detection of atrial fibrillation by implanted devices with wireless data transmission capability.

Niraj Varma1, Bruce Stambler, Sung Chun.   

Abstract

Remote telemetry may facilitate the management of implantable devices. We tested the reliability of a new automatic, wireless home monitoring (HM) system that archives data every 24 hours. We retrospectively analyzed archival data from 276 consecutive pacing system implants to define temporal atrial fibrillation (AF) patterns and associated ventricular rate. An "AF day" was defined by a >20%/24 hour mode switch (MS) duration, irrespective of the MS number. Management decisions resulting from transmissions were noted. A pilot study confirmed that 89% of 22,356 transmissions were successful, of which >90% were received in <5 minutes. Data integrity was 100% preserved. Overall, AF developed in 29 patients (10.5%), representing a total of 645 AF days (mean = 22.2 +/- 29.6 AF, median = 9 days), over 12 +/- 2 months of monitoring. AF was infrequent (<AF 30 days/year) in 80% of patients. When AF did occur, 83% patients had >/=1 day during which the AF burden was >50% of 24 hours. Ventricular rates during 645 AF days in 29 patients averaged 95.1 +/- 9.9 beats/min (median = 94 beats/min). Ventricular rates were >80 beats/min in 25 +/- 30 AF days (median = 11 days). HM enabled rapid anticoagulation decisions. In recipients of implantable devices, automatic wireless telemetry with HM was efficient and reliable. Its application may overcome some current challenges in AF management by early notification and precise measurement of both AF burden and ventricular rate during AF.

Entities:  

Mesh:

Year:  2005        PMID: 15683480     DOI: 10.1111/j.1540-8159.2005.00083.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  24 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  [Home monitoring of an incessant VT in an ICD patient].

Authors:  N Reinsch; D Woydowski; H Schön; M Buddensiek; W Weissenberger; R Erbel; T Konorza
Journal:  Herz       Date:  2010-12-23       Impact factor: 1.443

Review 3.  Management of atrial fibrillation--what are the possibilities of early detection with home monitoring?

Authors:  R P Ricci; M Russo; M Santini
Journal:  Clin Res Cardiol       Date:  2006       Impact factor: 5.460

4.  Remote monitoring in implantable defibrillator therapy.

Authors:  D A M J Theuns; L S Jordaens
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

Review 5.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

6.  Therapeutic implications of automatic home monitoring of implantable cardiac devices.

Authors:  Niraj Varma
Journal:  Curr Treat Options Cardiovasc Med       Date:  2009-10

Review 7.  Internet-based device-assisted remote monitoring of cardiovascular implantable electronic devices: an evidence-based analysis.

Authors:  G Pron; L Ieraci; K Kaulback
Journal:  Ont Health Technol Assess Ser       Date:  2012-01-01

8.  A prospective comparison of remote monitoring systems in implantable cardiac defibrillators: potential effects of frequency of transmissions.

Authors:  Ermenegildo de Ruvo; Luigi Sciarra; Anna Maria Martino; Marco Rebecchi; Renzo Venanzio Iulianella; Francesco Sebastiani; Alessandro Fagagnini; Alessio Borrelli; Antonio Scarà; Domenico Grieco; Claudia Tota; Federica Stirpe; Leonardo Calò
Journal:  J Interv Card Electrophysiol       Date:  2016-01       Impact factor: 1.900

Review 9.  [Home Monitoring with implantable ICD--a diagnostic innovation?].

Authors:  W Jung; R Birkemeyer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-09

10.  "We as Human Beings Get Farther and Farther Apart": the experiences of patients with remote monitoring systems.

Authors:  Abigale L Ottenberg; Keith M Swetz; Luke A Mueller; Samantha Gerhardson; Paul S Mueller
Journal:  Heart Lung       Date:  2013-04-10       Impact factor: 2.210

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.