Literature DB >> 15681194

A separation-free amperometric immunosensor for vitellogenin based on screen-printed carbon arrays modified with a conductive polymer.

Farzana Darain1, Doeg Su Park, Jang-Su Park, Seung-Cheol Chang, Yoon-Bo Shim.   

Abstract

A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM. Horseradish peroxidase (HRP) and a monoclonal antibody (anti-Vtg) specific to carp Vtg were covalently attached onto the polymer modified SPCAs. The immobilization of HRP and anti-Vtg onto the polymer-coated SPCAs was examined using cyclic voltammetry and quartz crystal microbalance studies. In order to detect the amount of Vtg, glucose oxidase (GOx)-labelled Vtg bound to the sensor surface under competition with the Vtg analyte was quantified amperometrically using glucose as a substrate. The performance of the eight sensors in arrays was evaluated by obtaining the calibration plots for Vtg. The sensor arrays exhibit a linear range of the Vtg concentration from 0.25 to 7.8 ng/ml and the detection limit was determined to be 0.09 ng/ml. Furthermore, the performance of the immunosensor for the determination of Vtg was evaluated by a standard addition method performed in fish serum samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15681194     DOI: 10.1016/j.bios.2004.07.006

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Electrochemical Sensors Based on Organic Conjugated Polymers.

Authors:  Md Aminur Rahman; Pankaj Kumar; Deog-Su Park; Yoon-Bo Shim
Journal:  Sensors (Basel)       Date:  2008-01-09       Impact factor: 3.576

2.  Electrochemical detection of mismatched DNA using a MutS probe.

Authors:  Minseon Cho; Sohyun Lee; Se-Young Han; Jin-Young Park; Md Aminur Rahman; Yoon-Bo Shim; Changill Ban
Journal:  Nucleic Acids Res       Date:  2006-06-13       Impact factor: 16.971

3.  Preparation of Graphene Quantum Dots by Visible-Fenton Reaction and Ultrasensitive Label-Free Immunosensor for Detecting Lipovitellin of Paralichthys Olivaceus.

Authors:  Ailing Yang; Yue Su; Zhenzhong Zhang; Huaidong Wang; Chong Qi; Shaoguo Ru; Jun Wang
Journal:  Biosensors (Basel)       Date:  2022-04-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.