Literature DB >> 15681193

L-lactate measures in brain tissue with ceramic-based multisite microelectrodes.

Jason J Burmeister1, Michael Palmer, Greg A Gerhardt.   

Abstract

A newly developed multisite array microelectrode for in vivo measurements of L-lactate is presented. The resulting microelectrode is composed of three functional layers. First, Nafion is used to repel interfering electroactive anions, such as ascorbate. Second, L-lactate oxidase immobilized onto the recording sites is used to convert L-lactate to hydrogen peroxide. The H2O2 produced is proportional to L-lactate concentrations and is quantified at the platinum recording sites. Third, a layer of polyurethane is coated over the L-lactate oxidase to adjust the linear range of the microelectrode to one that is compatible with in vivo measurements. This layer reduces the amount of L-lactate that diffuses to the enzyme while not significantly limiting oxygen diffusion. The resulting L-lactate microelectrodes were linear to 20 mM (R2 = 0.997 +/- 0.001) and beyond in some cases with detection limits of 0.078 +/- 0.013 mM (n = 12). The selectivity and response time of these electrodes make them suitable for in vivo measurements in brain tissue. Self-referencing recordings may be utilized to further improve the selectivity of the recordings. However this is not necessary for most applications in the brain, because the resting and stimulated levels of dopamine (DA), norepinephrine (NE), and other potentially interfering cations are two to three orders of magnitude lower than that of in vivo L-lactate, which is in the millimolar range. Preliminary in vivo measures of L-lactate in the brain of anesthetized rats support that the microelectrodes are capable of measuring rapid endogenous changes in vivo.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15681193     DOI: 10.1016/j.bios.2004.07.003

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  17 in total

1.  Sleep slow-wave activity regulates cerebral glycolytic metabolism.

Authors:  Jonathan P Wisor; Michael J Rempe; Michelle A Schmidt; Michele E Moore; William C Clegern
Journal:  Cereb Cortex       Date:  2012-07-05       Impact factor: 5.357

2.  Real-time monitoring of extracellular adenosine using enzyme-linked microelectrode arrays.

Authors:  Jason M Hinzman; Justin L Gibson; Ryan D Tackla; Mark S Costello; Jason J Burmeister; Jorge E Quintero; Greg A Gerhardt; Jed A Hartings
Journal:  Biosens Bioelectron       Date:  2015-07-07       Impact factor: 10.618

Review 3.  Electrochemical techniques for subsecond neurotransmitter detection in live rodents.

Authors:  Kevin N Hascup; Erin R Hascup
Journal:  Comp Med       Date:  2014-08       Impact factor: 0.982

4.  RECENT DEVELOPMENTS IN ELECTROCHEMICAL SENSORS FOR THE DETECTION OF NEUROTRANSMITTERS FOR APPLICATIONS IN BIOMEDICINE.

Authors:  Rıfat Emrah Özel; Akhtar Hayat; Silvana Andreescu
Journal:  Anal Lett       Date:  2014-12-31       Impact factor: 2.329

5.  Methodology for rapid measures of glutamate release in rat brain slices using ceramic-based microelectrode arrays: basic characterization and drug pharmacology.

Authors:  Jorge E Quintero; François Pomerleau; Peter Huettl; Kirk W Johnson; James Offord; Greg A Gerhardt
Journal:  Brain Res       Date:  2011-05-18       Impact factor: 3.252

6.  Challenges of simultaneous measurements of brain extracellular GABA and glutamate in vivo using enzyme-coated microelectrode arrays.

Authors:  Jason J Burmeister; David A Price; François Pomerleau; Peter Huettl; Jorge E Quintero; Greg A Gerhardt
Journal:  J Neurosci Methods       Date:  2019-10-07       Impact factor: 2.390

7.  Simultaneous electroencephalography, real-time measurement of lactate concentration and optogenetic manipulation of neuronal activity in the rodent cerebral cortex.

Authors:  William C Clegern; Michele E Moore; Michelle A Schmidt; Jonathan Wisor
Journal:  J Vis Exp       Date:  2012-12-19       Impact factor: 1.355

8.  Histological studies of the effects of chronic implantation of ceramic-based microelectrode arrays and microdialysis probes in rat prefrontal cortex.

Authors:  Erin R Hascup; Sara af Bjerkén; Kevin N Hascup; Francois Pomerleau; Peter Huettl; Ingrid Strömberg; Greg A Gerhardt
Journal:  Brain Res       Date:  2009-07-03       Impact factor: 3.252

Review 9.  Next-generation interfaces for studying neural function.

Authors:  James A Frank; Marc-Joseph Antonini; Polina Anikeeva
Journal:  Nat Biotechnol       Date:  2019-08-12       Impact factor: 54.908

10.  Technological Barriers in the Use of Electrochemical Microsensors and Microbiosensors for in vivo Analysis of Neurological Relevant Substances.

Authors:  Bogdan Bucur
Journal:  Curr Neuropharmacol       Date:  2012-09       Impact factor: 7.363