Literature DB >> 15678551

Detection threshold of single SPIO-labeled cells with FIESTA.

Chris Heyn1, Chris V Bowen, Brian K Rutt, Paula J Foster.   

Abstract

MRI of superparamagnetic iron oxide (SPIO)-labeled cells has become a valuable tool for studying the in vivo trafficking of transplanted cells. Cellular detection with MRI is generally considered to be orders of magnitude less sensitive than other techniques, such as positron emission tomography (PET), single photon emission-computed tomography (SPECT), or optical fluorescence microscopy. However, an analytic description of the detection threshold for single SPIO-labeled cells and the parameters that govern detection has not been adequately provided. In the present work, the detection threshold for single SPIO-labeled cells and the effect of resolution and SNR were studied for a balanced steady-state free precession (SSFP) sequence (3D-FIESTA). Based on the results from both theoretical and experimental analyses, an expression that predicts the minimum detectable mass of SPIO (m(c)) required to detect a single cell against a uniform signal background was derived: m(c) = 5v/(K(fsl) x SNR), where v is the voxel volume, SNR is the image signal-to-noise ratio, and K(fsl) is an empirical constant measured to be 6.2 +/- 0.5 x 10(-5) microl/pgFe. Using this expression, it was shown that the sensitivity of MRI is not very different from that of PET, requiring femtomole quantities of SPIO iron for detection under typical micro-imaging conditions (100 microm isotropic resolution, SNR = 60). The results of this work will aid in the design of cellular imaging experiments by defining the lower limit of SPIO labeling required for single cell detection at any given resolution and SNR.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15678551     DOI: 10.1002/mrm.20356

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  66 in total

1.  In vivo cellular MRI of dendritic cell migration using micrometer-sized iron oxide (MPIO) particles.

Authors:  Roja Rohani; Sonali N de Chickera; Christy Willert; Yuhua Chen; Gregory A Dekaban; Paula J Foster
Journal:  Mol Imaging Biol       Date:  2011-08       Impact factor: 3.488

Review 2.  Imaging stem cells implanted in infarcted myocardium.

Authors:  Rong Zhou; Paul D Acton; Victor A Ferrari
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

3.  In vivo MRI discrimination between live and lysed iron-labelled cells using balanced steady state free precession.

Authors:  E J Ribot; P J Foster
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

4.  Long-term monitoring of transplanted human neural stem cells in developmental and pathological contexts with MRI.

Authors:  Raphael Guzman; Nobuko Uchida; Tonya M Bliss; Dongping He; Karen K Christopherson; David Stellwagen; Alexandra Capela; Joan Greve; Robert C Malenka; Michael E Moseley; Theo D Palmer; Gary K Steinberg
Journal:  Proc Natl Acad Sci U S A       Date:  2007-06-06       Impact factor: 11.205

Review 5.  Imaging of stem cells using MRI.

Authors:  Dara L Kraitchman; Jeff W M Bulte
Journal:  Basic Res Cardiol       Date:  2008-03       Impact factor: 17.165

Review 6.  Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applications.

Authors:  David E Sosnovik; Matthias Nahrendorf; Ralph Weissleder
Journal:  Basic Res Cardiol       Date:  2008-03       Impact factor: 17.165

7.  Carboxylated superparamagnetic iron oxide particles label cells intracellularly without transfection agents.

Authors:  Volker Mailänder; Myriam Ricarda Lorenz; Verena Holzapfel; Anna Musyanovych; Karin Fuchs; Markus Wiesneth; Paul Walther; Katharina Landfester; Hubert Schrezenmeier
Journal:  Mol Imaging Biol       Date:  2008-02-23       Impact factor: 3.488

Review 8.  Noninvasive imaging of islet transplantation and rejection.

Authors:  Jason L Gaglia
Journal:  Curr Diab Rep       Date:  2007-08       Impact factor: 4.810

9.  Sensitive and automated detection of iron-oxide-labeled cells using phase image cross-correlation analysis.

Authors:  Parker H Mills; Yi-Jen L Wu; Chien Ho; Eric T Ahrens
Journal:  Magn Reson Imaging       Date:  2008-05-02       Impact factor: 2.546

Review 10.  Detection and quantification of magnetically labeled cells by cellular MRI.

Authors:  Wei Liu; Joseph A Frank
Journal:  Eur J Radiol       Date:  2008-11-07       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.