| Literature DB >> 15674829 |
T Hayakawa1, M Yoshinari, K Nemoto.
Abstract
The immobilization of cell-adhesive proteins onto titanium implants improves biological response at the implant-tissue interface. Previous studies demonstrated the easy and direct attachment of fibronectin onto titanium with the use of a 2,2,2-trifluoroethanesulfonyl chloride (tresyl chloride) activation technique. The present study investigated the initial adsorption behavior of fibronectin on tresyl chloride-activated titanium by the quartz-crystal microbalance-dissipation (QCM-D) technique. The crystal resonant frequency and the dissipation shift of the oscillator were simultaneously measured by the injection of fibronectin/phosphate-buffered saline solution (pH = 7.4). The tresyl chloride-activated titanium surface showed a faster and greater decrease in frequency than that of untreated titanium, indicating that a greater amount of fibronectin was adsorbed in the former case during a 120-min adsorption. The dissipation-frequency plots revealed that, during the initial stage of adsorption, the bond between fibronectin and tresyl chloride-activated titanium is stronger than that between fibronectin and untreated titanium. The QCM-D technique can provide new insights into the adsorption mechanism of fibronectin. (c) 2005 Wiley Periodicals, Inc.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15674829 DOI: 10.1002/jbm.b.30207
Source DB: PubMed Journal: J Biomed Mater Res B Appl Biomater ISSN: 1552-4973 Impact factor: 3.368