Literature DB >> 15673848

Segmental myocardial wall motion during minimally invasive coronary artery bypass grafting using open and endoscopic surgical techniques.

S Mierdl1, C Byhahn, V Lischke, T Aybek, G Wimmer-Greinecker, S Dogan, S Viehmeyer, P Kessler, Klaus Westphal.   

Abstract

Current options for minimally invasive surgical treatment of single-vessel coronary artery disease include beating heart procedures without cardiopulmonary bypass (CPB) via mini-thoracotomy (MIDCAB) and totally endoscopic robot-assisted techniques (TECAB) with CPB. Both procedures are associated with potential myocardial stress before revascularization, such as single-lung ventilation (SLV), temporary coronary artery occlusion, cardiac luxation, intrathoracic carbon dioxide insufflation, and extended CPB and operating time. In this echocardiographic study we sought to evaluate the extent of intraoperative segmental wall motion abnormalities (SWMA) during MIDCAB and TECAB surgery and to identify factors affecting SWMA. Forty-six patients with single-vessel coronary artery disease were studied. Sixteen patients were operated using the MIDCAB technique and 30 patients with TECAB. In both groups sequential transesophageal echocardiograms were recorded during the entire procedure. Hemodynamic data and oxygenation variables were acquired simultaneously. In both groups, mild but obvious perioperative SWMA were identified and noted to increase during the course of the operation. These SWMA were more pronounced in the TECAB group. Independent of operating time, these changes disappeared completely after revascularization. No significant hemodynamic compromise was observed. We conclude that MIDCAB and TECAB techniques are associated with significant perioperative SWMA. The appearance of more profound SWMA in the TECAB group compared with the MIDCAB patients might have been the result of intrathoracic CO(2) insufflation, as SLV was used in both groups. No persistent SWMA or post-CPB SWMA were apparent in either group. More extensive intraoperative ventricular SWMA was detected in the TECAB group, suggesting that a more frequent risk for right ventricular dysfunction may exist during TECAB procedures.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15673848     DOI: 10.1213/01.ANE.0000143565.18784.54

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

Review 1.  Anesthetic issues for robotic cardiac surgery.

Authors:  Wendy K Bernstein; Andrew Walker
Journal:  Ann Card Anaesth       Date:  2015 Jan-Mar

Review 2.  Robotic surgery: disruptive innovation or unfulfilled promise? A systematic review and meta-analysis of the first 30 years.

Authors:  Alan Tan; Hutan Ashrafian; Alasdair J Scott; Sam E Mason; Leanne Harling; Thanos Athanasiou; Ara Darzi
Journal:  Surg Endosc       Date:  2016-02-19       Impact factor: 4.584

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.