Literature DB >> 15671369

Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study.

Stefania M R Rizzo1, Mannudeep K Kalra, Michael M Maher, Michael A Blake, Thomas L Toth, Sanjay Saini.   

Abstract

OBJECTIVE: Our objective was to assess the effect of orthopedic metallic prostheses on radiation dose associated with MDCT using z-axis automatic tube-current modulation and a fixed tube current in a phantom and patient study.
CONCLUSION: Z-modulation is associated with a 34.1% increase in the mean tube current-time product and no change in the extent of streak artifacts in patients with a metallic prosthesis, compared with patients without a prosthesis. However, compared with the fixed-tube-current technique, z-modulation is associated with a 28.9% decrease in the mean tube current-time product.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15671369     DOI: 10.2214/ajr.184.2.01840491

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

Authors:  Hyun Kyong Lim; Kyoung Ho Lee; So Yeon Kim; Kil Joong Kim; Bohyoung Kim; Hyunna Lee; Seong Ho Park; Jeffrey H Yanof; Seung-Sik Hwang; Young Hoon Kim
Journal:  Eur Radiol       Date:  2010-08-11       Impact factor: 5.315

2.  Positive enteric contrast material for abdominal and pelvic CT with automatic exposure control: what is the effect on patient radiation exposure?

Authors:  Zhen J Wang; Katherine S Chen; Robert Gould; Fergus V Coakley; Yanjun Fu; Benjamin M Yeh
Journal:  Eur J Radiol       Date:  2011-04-13       Impact factor: 3.528

3.  Should the automatic exposure control system of CT be disabled when scanning patients with endoaortic stents or mechanical heart valves? A phantom study.

Authors:  Giovanni Di Leo; Chiara Spadavecchia; Moreno Zanardo; Francesco Secchi; Ivan Veronese; Marie Claire Cantone; Francesco Sardanelli
Journal:  Eur Radiol       Date:  2016-12-12       Impact factor: 5.315

4.  Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation.

Authors:  Hyun Woo Goo; Hyum Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-02-25

Review 5.  Computed tomography dose optimisation in cystic fibrosis: A review.

Authors:  Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O'Neill; Kevin Murphy; Owen J O'Connor; Michael Maher
Journal:  World J Radiol       Date:  2016-04-28

6.  A questionnaire survey reviewing radiologists' and clinical specialist radiographers' knowledge of CT exposure parameters.

Authors:  S J Foley; M G Evanoff; L A Rainford
Journal:  Insights Imaging       Date:  2013-09-05

7.  Metal implants influence CT scan parameters leading to increased local radiation exposure: A proposal for correction techniques.

Authors:  Ok Kyu Song; Yong Eun Chung; Nieun Seo; Song-Ee Baek; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim
Journal:  PLoS One       Date:  2019-08-23       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.