Literature DB >> 15671353

Metallic stent placement for treating peripheral outflow lesions in native arteriovenous fistula hemodialysis patients after insufficient balloon dilatation.

Huay-Ben Pan1, Huei-Lung Liang, Yih-Huie Lin, Hsiao-Min Chung, Tung-Ho Wu, Chiung-Yu Chen, Hua-Chang Fang, Clement K-H Chen, Pin-Hon Lai, Chien-Fang Yang.   

Abstract

OBJECTIVE: The purpose of this study was to report our experience with metallic stent placement in the peripheral outflow veins in native arteriovenous fistula (A-V fistula) hemodialysis patients after insufficient balloon dilatation.
MATERIALS AND METHODS: During the past 4 years, 12 A-V fistula dialysis patients in our hospital underwent metallic stent placement in the peripheral outflow veins to restore vascular access. The indications for metallic stent placement in our study included (1) recoil stenosis of outflow vein in six patients; (2) outflow venous rupture in two patients and dissection in one patient; and (3) large residual adherent thrombus in outflow aneurysms in three patients with thrombosed (arteriovenous) access. Self-expandable Wallstent or Jostent (Jomed, Abbott Laboratories) of appropriate size (6-10 mm in diameter) was chosen for use in these patients. Kaplan-Meier survival analysis was used to calculate the access patency rates.
RESULTS: Twelve patients received stents. Eleven patients (92%) underwent successful dialysis after the procedure. One patient experienced complications due to incorrect positioning of the stent at the anastomotic site, causing flow compromise. The primary patency (+/- standard error) of the vascular access at 3, 6, 12, and 24 months was 92% +/- 8%, 81% +/- 12%, 31% +/- 17%, and 31% +/- 17%, respectively. The secondary patency of the vascular access at 3 months was 92% +/- 8%, and 82% +/- 12% at 6, 12, and 24 months each.
CONCLUSION: Metallic stent placement is safe and effective in treating peripheral venous lesions in native A-V fistula hemodialysis patients after unsatisfactory balloon dilatation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15671353     DOI: 10.2214/ajr.184.2.01840403

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Advanced Stent Graft Treatment of Venous Stenosis Affecting Hemodialysis Vascular Access: Case Illustrations.

Authors:  Darshan Patel; Charles E Ray; R Peter Lokken; James T Bui; Andrew J Lipnik; Ron C Gaba
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

2.  Percutaneous translumbar inferior vena cava catheter placement for long-term hemodialysis treatment.

Authors:  Edwin Rodriguez-Cruz; Melvin Bonilla; Juan Perez
Journal:  Pediatr Nephrol       Date:  2006-11-23       Impact factor: 3.714

3.  Stent graft deployment in haemodialysis fistula: patency rates in partially thrombosed aneurysm and residual thrombi.

Authors:  José García-Medina; Ana B Maldonado-Cárceles; Juan J García-Alfonso; Julián J Árense-Gonzalo; Alberto M Torres-Cantero
Journal:  Clin Kidney J       Date:  2020-02-10

4.  Efficacy of SMART Stent Placement for Salvage Angioplasty in Hemodialysis Patients with Recurrent Vascular Access Stenosis.

Authors:  Shingo Hatakeyama; Terumasa Toikawa; Akiko Okamoto; Hayato Yamamoto; Kengo Imanishi; Teppei Okamoto; Noriko Tokui; Yuichiro Suzuki; Naoki Sugiyama; Atsushi Imai; Yasuhiro Hashimoto; Shigemasa Kudo; Takahiro Yoneyama; Takuya Koie; Noritaka Kamimura; Hisao Saitoh; Tomihisa Funyu; Chikara Ohyama
Journal:  Int J Nephrol       Date:  2011-11-20

5.  Endovascular stent placement of juxtaanastomotic stenosis in native arteriovenous fistula after unsuccessful balloon angioplasty.

Authors:  Burak Ozkan; Durmus Güngör; Utku Mahir Yıldırım; Ali Harman; Ozgur Ozen; Cüneyt Aytekin
Journal:  Iran J Radiol       Date:  2013-08-30       Impact factor: 0.212