Literature DB >> 15663468

Mucous membrane and lower respiratory building related symptoms in relation to indoor carbon dioxide concentrations in the 100-building BASE dataset.

Christine A Erdmann1, Michael G Apte.   

Abstract

UNLABELLED: Indoor air pollutants are a potential cause of building related symptoms and can be reduced by increasing ventilation rates. Indoor carbon dioxide (CO(2)) concentration is an approximate surrogate for concentrations of occupant-generated pollutants and for ventilation rate per occupant. Using the US EPA 100 office-building BASE Study dataset, we conducted multivariate logistic regression analyses to quantify the relationship between indoor CO(2) concentrations (dCO(2)) and mucous membrane (MM) and lower respiratory system (LResp) building related symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. In addition, we tested the hypothesis that certain environmentally mediated health conditions (e.g., allergies and asthma) confer increased susceptibility to building related symptoms. Adjusted odds ratios (ORs) for statistically significant, dose-dependent associations (P < 0.05) for combined mucous membrane, dry eyes, sore throat, nose/sinus congestion, sneeze, and wheeze symptoms with 100 p.p.m. increases in dCO(2) ranged from 1.1 to 1.2. Building occupants with certain environmentally mediated health conditions were more likely to report that they experience building related symptoms than those without these conditions (statistically significant ORs ranged from 1.5 to 11.1, P < 0.05). PRACTICAL IMPLICATIONS: These results suggest that provision of sufficient per-person outdoor ventilation air, could significantly decrease prevalence of selected building related symptoms. The observed relationship between indoor minus outdoor CO(2) concentrations and mucous membrane and lower respiratory symptoms suggests that air contaminants are implicated in the etiology of building related symptoms. Levels of indoor air pollutants that are suspected to cause building related symptoms could be reduced by increasing ventilation rates, improving ventilation effectiveness, or reducing sources of indoor air pollutants, if known.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15663468     DOI: 10.1111/j.1600-0668.2004.00298.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  10 in total

1.  Health outcomes and green renovation of affordable housing.

Authors:  Jill Breysse; David E Jacobs; William Weber; Sherry Dixon; Carol Kawecki; Susan Aceti; Jorge Lopez
Journal:  Public Health Rep       Date:  2011 May-Jun       Impact factor: 2.792

2.  Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds.

Authors:  Chung-Yen Lu; Jia-Min Lin; Ying-Yi Chen; Yi-Chun Chen
Journal:  Int J Environ Res Public Health       Date:  2015-05-27       Impact factor: 3.390

3.  Carbon Dioxide Concentrations and Temperatures within Tour Buses under Real-Time Traffic Conditions.

Authors:  Chun-Fu Chiu; Ming-Hung Chen; Feng-Hsiang Chang
Journal:  PLoS One       Date:  2015-04-29       Impact factor: 3.240

Review 4.  Airborne environmental injuries and human health.

Authors:  Andrea T Borchers; Christopher Chang; Carl L Keen; M Eric Gershwin
Journal:  Clin Rev Allergy Immunol       Date:  2006-08       Impact factor: 8.667

5.  Relationship between sick building syndrome and indoor air quality among hospital staff.

Authors:  Inci Arikan; Ömer Faruk Tekin; Oğuzhan Erbas
Journal:  Med Lav       Date:  2018-12-20       Impact factor: 1.275

6.  Graphene Aerogels for In Situ Synthesis of Conductive Poly(para-phenylenediamine) Polymers, and Their Sensor Application.

Authors:  Sahin Demirci; Mehmet Can; Nurettin Sahiner
Journal:  Micromachines (Basel)       Date:  2020-06-27       Impact factor: 2.891

7.  Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project.

Authors:  Vithawat Surawattanasakul; Wachiranun Sirikul; Ratana Sapbamrer; Kampanat Wangsan; Jinjuta Panumasvivat; Pheerasak Assavanopakun; Supang Muangkaew
Journal:  Int J Environ Res Public Health       Date:  2022-08-31       Impact factor: 4.614

8.  Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 concentrations on human decision-making performance.

Authors:  Usha Satish; Mark J Mendell; Krishnamurthy Shekhar; Toshifumi Hotchi; Douglas Sullivan; Siegfried Streufert; William J Fisk
Journal:  Environ Health Perspect       Date:  2012-09-20       Impact factor: 9.031

9.  Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schools.

Authors:  M J Mendell; E A Eliseeva; M M Davies; M Spears; A Lobscheid; W J Fisk; M G Apte
Journal:  Indoor Air       Date:  2013-04-22       Impact factor: 5.770

10.  Sick building syndrome and perceived indoor environmental quality: A survey of apartment buildings in Hong Kong.

Authors:  Siu-Kei Wong; Lawrence Wai-Chung Lai; Daniel Chi-Wing Ho; Kwong-Wing Chau; Cindy Lo-Kuen Lam; Chris Hung-Fai Ng
Journal:  Habitat Int       Date:  2009-04-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.