Literature DB >> 15663465

VOC- and SVOC-emissions from adhesives, floor coverings and complete floor structures.

Olaf Wilke1, Oliver Jann, Doris Brödner.   

Abstract

UNLABELLED: Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 degrees C, 50% relative humidity and an area specific air flow rate of q = 1.25 m(3)/m(2) h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. PRACTICAL IMPLICATIONS: This paper gives a survey of possible emissions of VOCs and SVOCs from flooring materials and adhesives. On the example of these materials it is shown that the determination of SVOC-emissions from materials is important because after a few weeks the emission rates for SVOCs might be higher than for VOCs. In the real indoor environment SVOCs will be probably adsorbed to dust but by means of emission test chambers or cells the determination of emission rates from materials is possible. With the knowledge of this "emission potential" it is possible to estimate also the release of SVOCs into the (indoor) environment.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15663465     DOI: 10.1111/j.1600-0668.2004.00314.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  16 in total

1.  Differential determination of plasticizers and organophosphorus flame retardants in residential indoor air in Japan.

Authors:  Shinji Takeuchi; Toshiko Tanaka-Kagawa; Ikue Saito; Hiroyuki Kojima; Kazuo Jin; Masayuki Satoh; Satoshi Kobayashi; Hideto Jinno
Journal:  Environ Sci Pollut Res Int       Date:  2015-06-24       Impact factor: 4.223

2.  Longitudinal variations in indoor VOC concentrations after moving into new apartments and indoor source characterization.

Authors:  Seung-Ho Shin; Wan-Kuen Jo
Journal:  Environ Sci Pollut Res Int       Date:  2012-11-10       Impact factor: 4.223

3.  Dynamics of Residential Water-Soluble Organic Gases: Insights into Sources and Sinks.

Authors:  Sara M Duncan; Sophie Tomaz; Glenn Morrison; Marc Webb; Joanna Atkin; Jason D Surratt; Barbara J Turpin
Journal:  Environ Sci Technol       Date:  2019-01-31       Impact factor: 9.028

4.  INTEGRATING HEALTH INTO BUILDINGS OF THE FUTURE.

Authors:  Leila Heidari; Margalit Younger; George Chandler; James Gooch; Paul Schramm
Journal:  J Sol Energy Eng       Date:  2016-11-29       Impact factor: 2.384

5.  Volatile pollutants emitted from selected liquid household products.

Authors:  Ki-Dong Kwon; Wan-Kuen Jo; Ho-Jin Lim; Woo-Sik Jeong
Journal:  Environ Sci Pollut Res Int       Date:  2008-08-08       Impact factor: 4.223

6.  Home renovation, family history of atopy, and respiratory symptoms and asthma among children living in China.

Authors:  Guang-Hui Dong; Zhengmin Min Qian; Jing Wang; Edwin Trevathan; Miao-Miao Liu; Da Wang; Wan-Hui Ren; Weiqing Chen; Maayan Simckes; Alan Zelicoff
Journal:  Am J Public Health       Date:  2013-11-14       Impact factor: 9.308

7.  Indoor exposure to phthalates and polycyclic aromatic hydrocarbons (PAHs) to Canadian children: the Kingston allergy birth cohort.

Authors:  Yuchao Wan; Michelle L North; Garthika Navaranjan; Anne K Ellis; Jeffrey A Siegel; Miriam L Diamond
Journal:  J Expo Sci Environ Epidemiol       Date:  2021-04-14       Impact factor: 5.563

Review 8.  A critical review of naphthalene sources and exposures relevant to indoor and outdoor air.

Authors:  Chunrong Jia; Stuart Batterman
Journal:  Int J Environ Res Public Health       Date:  2010-07-20       Impact factor: 3.390

9.  Emission rates of volatile organic compounds released from newly produced household furniture products using a large-scale chamber testing method.

Authors:  Duy Xuan Ho; Ki-Hyun Kim; Jong Ryeul Sohn; Youn Hee Oh; Ji-Won Ahn
Journal:  ScientificWorldJournal       Date:  2011-09-08

10.  Volatile organic compounds enhance allergic airway inflammation in an experimental mouse model.

Authors:  Ulrike Bönisch; Alexander Böhme; Tibor Kohajda; Iljana Mögel; Nicole Schütze; Martin von Bergen; Jan C Simon; Irina Lehmann; Tobias Polte
Journal:  PLoS One       Date:  2012-07-03       Impact factor: 3.240

View more