A novel approach to the statistical evaluation of media fill tests by the difference from no contamination data.

Kunio Kawamura1, Hiroshi Abe.   

Abstract

It is obvious that, in the media fill test and process simulation test, positive numbers in total fills should not have any significant difference from zero or asepsis. There are many reports concerning the definition of "sterility" or "asepsis." However, any scientific and practical methods to demonstrate "no significant difference from zero" have not been reported up to now. The existing criteria, such as "less than 0.1%," "less than 0.05%," and "less than two positives" are not appropriate to assure the integrity of processes, and sometimes lead to erroneous results. The purpose of this report is to demonstrate novel, reasonable and practical methods and criteria based on scientific and statistical consideration. According to the ISO 13408-1 Aseptic Processing of Health Care Products, Part 1 (1998), General Requirement for Aseptic Processing, the action level for the number of positive units in media fill tests is specified as 0.1%, and the alert level is 0.05%. In this paper it is shown that the existing ISO standard and other official methods are inappropriate in that zero contaminated units (sterile product) is outside the confidence range of probable distribution of contaminated units, even though the contaminated units are less than 0.1% in larger numbers of fills, and even less than 0.05%. This indicates that the limit of 0.1% or 0.05% is inappropriate in cases of larger numbers of fills. For sterile products, the number of contaminated units other than "zero" at the statistical confidence range must be judged to be contaminated units in process and as non-sterile. In order to harmonize this criteria-"no significant difference from zero"-with the existing criteria, the new criteria may be combined with only the existing criteria of 0.05% in smaller number of fills.

Mesh:

Year:  2004        PMID: 15663062

Source DB:  PubMed          Journal:  PDA J Pharm Sci Technol        ISSN: 1079-7440


  2 in total

1.  Comparison of Tunable Diode Laser Absorption Spectroscopy and Isothermal Micro-calorimetry for Non-invasive Detection of Microbial Growth in Media Fills.

Authors:  David Brueckner; David Roesti; Ulrich Georg Zuber; Rainer Schmidt; Stefan Kraehenbuehl; Gernot Bonkat; Olivier Braissant
Journal:  Sci Rep       Date:  2016-06-10       Impact factor: 4.379

2.  Implementation and validation of an in-house combined fluorescein/media-fill test to qualify radiopharmacy operators.

Authors:  Cyril Fersing; Emmanuel Deshayes; Sarah Langlet; Laurence Calas; Vincent Lisowski; Pierre Olivier Kotzki
Journal:  EJNMMI Radiopharm Chem       Date:  2021-01-07