Literature DB >> 15662502

[Influence of cutoff filters on reading behavior in age-related macular degeneration].

K Rohrschneider1, M Stritzke, D Ziese, Y Bayer.   

Abstract

BACKGROUND: Cutoff filters may improve contrast sensitivity in different retinal dystrophies and therefore lead to improved visual function. We investigated whether cutoff filters result in improved reading ability in age-related macular degeneration (AMD).
METHODS: Reading performance was examined in 22 patients with AMD aged 63-91 years (visual acuity 0.1-0.5) using the Radner reading charts. These charts were presented in random order either with or without cutoff filters (Zeiss CF 540 and CF 580) monocularly to the better eye using a defined luminance of the test charts of 105 cd/m(2).
RESULTS: Using the CF 540 cutoff filter, there was no significant change in visual acuity while there was a tendency to decrease. Calculating the LogRAD score, which takes reading errors into account, three patients improved by one line, while nine deteriorated, six of them by one line or more. There was no significant improvement using the CF 580 compared to either the CF 540 or to normal reading glasses.
CONCLUSIONS: Overall, we found no measurable improvement using the CF 540 cutoff filter. The cutoff filter CF 580, tested for additional comparison, did not show any advantage.

Entities:  

Mesh:

Year:  2005        PMID: 15662502     DOI: 10.1007/s00347-004-1154-6

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  15 in total

Review 1.  Do tinted lenses or filters improve visual performance in low vision? A review of the literature.

Authors:  Frank Eperjesi; Colin W Fowler; Bruce J W Evans
Journal:  Ophthalmic Physiol Opt       Date:  2002-01       Impact factor: 3.117

2.  Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability.

Authors:  Eva Stifter; Franz König; Thomas Lang; Peter Bauer; Sibylla Richter-Müksch; Michaela Velikay-Parel; Wolfgang Radner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-12-10       Impact factor: 3.117

3.  New design principles for visual acuity letter charts.

Authors:  I L Bailey; J E Lovie
Journal:  Am J Optom Physiol Opt       Date:  1976-11

4.  Vision enhancement using a short wavelength light-absorbing filter.

Authors:  S Zigman
Journal:  Optom Vis Sci       Date:  1990-02       Impact factor: 1.973

5.  Light filters to improve vision.

Authors:  S Zigman
Journal:  Optom Vis Sci       Date:  1992-04       Impact factor: 1.973

6.  Fundus-controlled examination of reading in eyes with macular pathology.

Authors:  K Rohrschneider; C Bethke-Jaenicke; M Becker; F E Kruse; A Blankenagel; H E Völcker
Journal:  Ger J Ophthalmol       Date:  1996-09

7.  Psychophysics of reading--II. Low vision.

Authors:  G E Legge; G S Rubin; D G Pelli; M M Schleske
Journal:  Vision Res       Date:  1985       Impact factor: 1.886

8.  Eye movements during reading: further case reports.

Authors:  K J Ciuffreda; R V Kenyon; L Stark
Journal:  Am J Optom Physiol Opt       Date:  1985-12

9.  Effect of light filters on contrast sensitivity function in normal and retinal degeneration subjects.

Authors:  L E Leguire; S Suh
Journal:  Ophthalmic Physiol Opt       Date:  1993-04       Impact factor: 3.117

10.  [Satisfaction with low vision aids].

Authors:  K Rohrschneider; R Kiel; V Pavlovska; A Blankenagel
Journal:  Klin Monbl Augenheilkd       Date:  2002-07       Impact factor: 0.700

View more
  1 in total

Review 1.  [Edge filters : Medical indications and clinical application].

Authors:  K Rohrschneider; M Bach
Journal:  Ophthalmologe       Date:  2018-11       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.