Literature DB >> 15657706

Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode.

Xue-Cai Tan1, Yuan-Xin Tian, Pei-Xiang Cai, Xiao-Yong Zou.   

Abstract

An improved amperometric glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film, which was prepared from chitosan (CS) and methyltrimethoxysilane (MTOS), on the surface of Prussian blue (PB)-modified glass carbon electrode was developed. The film was characterized by FT-IR. Effects of some experimental variables such as ratio of CS to silica, buffer pH, temperature, and applied potential on the current response of the biosensor were investigated. The biosensor fabricated under optimal conditions had a linear response to glucose over the range 5.0 x 10(-5) to 2.6 x 10(-2) M with a correlation coefficient of 0.9948 and a detection limit of 8.0 x 10(-6) M based on S/N = 3. The biosensor had a fast response time of less than 10 s, a high sensitivity of 420 nA mM(-1), a long-term stability of over 60 days, and a good selectivity. The apparent Michaelis-Menten constant K(m) was found to be 3.2 x 10(-3) M. The activation energy for enzymatic reaction was calculated to be 21.9 kJ mol(-1). This method has been used to determine the glucose concentration in real human blood samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15657706     DOI: 10.1007/s00216-004-2956-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Silica-dispersed glucose oxidase for glucose sensing: in vitro testing in serum and blood and the effect of condensation pH.

Authors:  James M Harris; Gabriel P Lopez; William M Reichert
Journal:  Sens Actuators B Chem       Date:  2012-11       Impact factor: 7.460

2.  An amperometric glucose biosensor based on electrostatic force induced layer-by-layer GOD/chitosan/pyrite on a glassy carbon electrode.

Authors:  Tingting Ma; Yue Wang; Ying Hou; Enlei Wang; Guoqing Yin; Yasushi Hasebe; Zhiqiang Zhang
Journal:  Anal Sci       Date:  2022-04-01       Impact factor: 2.081

Review 3.  Carbon Anode in Carbon History.

Authors:  César A C Sequeira
Journal:  Molecules       Date:  2020-10-28       Impact factor: 4.411

4.  Amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin on a glassy carbon electrode modified with fe(3)o(4)/chitosan core-shell microspheres.

Authors:  Xue-Cai Tan; Jin-Lei Zhang; Sheng-Wei Tan; Dan-Dan Zhao; Zen-Wei Huang; Yan Mi; Zai-Yin Huang
Journal:  Sensors (Basel)       Date:  2009-08-05       Impact factor: 3.576

Review 5.  Biosensors in clinical chemistry - 2011 update.

Authors:  Paul D'Orazio
Journal:  Clin Chim Acta       Date:  2011-06-26       Impact factor: 3.786

Review 6.  Exploration of Chitinous Scaffold-Based Interfaces for Glucose Sensing Assemblies.

Authors:  Dipali R Bagal-Kestwal; Been-Huang Chiang
Journal:  Polymers (Basel)       Date:  2019-11-28       Impact factor: 4.329

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.