Literature DB >> 1565523

Intraoperative femoral fractures in cementless total hip arthroplasty.

P F Sharkey1, W J Hozack, R E Booth, R H Rothman.   

Abstract

Ten patients with intraoperative femoral fractures during primary cementless total hip arthroplasty were matched by age, sex, weight, diagnosis, and length of follow-up to 20 patients who had primary cementless total hip arthroplasty without this complication. All fractures were identified in the operating room, and treatment was individualized for each case. Initial stability of the implant was felt to be satisfactory for all cases despite this complication. The mean follow-up was 2.3 years. In this series, no difference was found in clinical or roentgenographic results after cementless total hip arthroplasty between patients who had an intraoperative femoral fracture and patients who did not have this complication. If initial stability of the implant is satisfactory, despite intraoperative fracture, good clinical results can be expected with cementless total hip arthroplasty.

Entities:  

Mesh:

Year:  1992        PMID: 1565523

Source DB:  PubMed          Journal:  Orthop Rev        ISSN: 0094-6591


  6 in total

1.  High incidence of intraoperative calcar fractures with the cementless CLS Spotorno stem.

Authors:  Carla Timmer; Davey M J M Gerhardt; Enrico de Visser; Marinus de Kleuver; Job L C van Susante
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-07

2.  Case report: Cementless stem stabilization after intraoperative fracture: a radiostereometric analysis.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2009-09-17       Impact factor: 4.176

3.  Intraoperative femur fracture is associated with stem and instrument design in primary total hip arthroplasty.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

4.  Peroperative fractures in uncemented total hip arthroplasty: results with a single design of stem implant.

Authors:  Ricardo Fernandez-Fernandez; Elena García-Elias; Enrique Gil-Garay
Journal:  Int Orthop       Date:  2007-01-20       Impact factor: 3.075

5.  Conclusions.

Authors:  E Gagneux; L Jeunet; P Vichard
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

6.  An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur.

Authors:  Najmul Huda; Ajay Pant; M Aslam
Journal:  J Orthop Case Rep       Date:  2015 Jul-Sep
  6 in total