OBJECTIVES: We investigated whether embolic particles could be detected as high-intensity transient signals (HITS) with a Doppler guide wire during percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) We also assessed whether these signals could be reduced using a distal protection (DP) device. BACKGROUND: Embolization of thrombi and plaque components to the microcirculation is a major complication of PCI in patients with AMI. Embolic particles running in the cerebral artery are detected as HITS by transcranial Doppler ultrasound. METHODS: We prospectively studied 16 consecutive patients with AMI who underwent direct PCI within 24 h after the onset of symptoms. A PercuSurge GuardWire (MedtronicAVE, Santa Rosa, California) was used as the DP device. Eight patients were randomly assigned to the non-DP group, and the remaining eight were assigned to the DP group. Coronary flow velocity was recorded continuously from before the first balloon inflation to after balloon deflation. RESULTS: All patients in the non-DP group had HITS detected (12 +/- 9 counts) within five consecutive beats (4 +/- 1 beat) after balloon deflation, but none were detected in any of the patients in the DP group. CONCLUSIONS: The Doppler guide wire can be used to visually detect and count emboli as HITS, and the DP device is effective for prevention of distal embolization.
RCT Entities:
OBJECTIVES: We investigated whether embolic particles could be detected as high-intensity transient signals (HITS) with a Doppler guide wire during percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) We also assessed whether these signals could be reduced using a distal protection (DP) device. BACKGROUND: Embolization of thrombi and plaque components to the microcirculation is a major complication of PCI in patients with AMI. Embolic particles running in the cerebral artery are detected as HITS by transcranial Doppler ultrasound. METHODS: We prospectively studied 16 consecutive patients with AMI who underwent direct PCI within 24 h after the onset of symptoms. A PercuSurge GuardWire (MedtronicAVE, Santa Rosa, California) was used as the DP device. Eight patients were randomly assigned to the non-DP group, and the remaining eight were assigned to the DP group. Coronary flow velocity was recorded continuously from before the first balloon inflation to after balloon deflation. RESULTS: All patients in the non-DP group had HITS detected (12 +/- 9 counts) within five consecutive beats (4 +/- 1 beat) after balloon deflation, but none were detected in any of the patients in the DP group. CONCLUSIONS: The Doppler guide wire can be used to visually detect and count emboli as HITS, and the DP device is effective for prevention of distal embolization.
Authors: Maythem Saeed; Steve W Hetts; Loi Do; Sammir M Sullivan; Mark W Wilson Journal: Int J Cardiovasc Imaging Date: 2012-10-13 Impact factor: 2.357
Authors: Diana M Sobieraj; C Michael White; Jeffrey Kluger; Vanita Tongbram; Jennifer Colby; Wendy T Chen; Sagar S Makanji; Soyon Lee; Ajibade Ashaye; Craig I Coleman Journal: BMC Cardiovasc Disord Date: 2011-12-20 Impact factor: 2.298