Literature DB >> 15651635

Automatic real-time surveillance of eye position and gating for stereotactic radiotherapy of uveal melanoma.

Bernhard Petersch1, Joachim Bogner, Karin Dieckmann, Richard Pötter, Dietmar Georg.   

Abstract

A new prototype (hardware and software) for monitoring eye movements using a noninvasive technique for gated linac-based stereotactic radiotherapy (SRT) of uveal melanoma was developed. The prototype was tested within the scope of a study for 11 patients. Eye immobilization was achieved by having the patient fixate a light source integrated into the system. The system is used in conjunction with a Head&Neck mask system for immobilization, and uses infrared tracking technology for positioning (both BrainLAB AG Heimstetten/Germany). It was used during CT and MR image acquisition as well as during all of five treatment fractions (6 MeV, 5 x 12 Gy to 80% isodose) to guarantee identical patient setup and eye rotational state during treatment planning and treatment delivery. Maximum temporal and angular deviations tolerated during treatment delivery can be chosen by the physician, the radiation then being interrupted automatically and instantaneously if those criteria are being exceeded during irradiation. A graphical user interface displays life video images of the treated eye and information about the current and previous rotational deviation of the eye from its reference treatment position. The physician thus has online access to data directly linked to the success of the treatment and possible side effects. Mean angular deviations during CT/MR scans and treatment deliveries ranged from 1.61 degrees to 3.64 degrees (standard deviations 0.87 degrees to 2.09 degrees ) which is in accordance with precision requirements for SRT. Typical situations when preset deviation criteria were exceeded are slow drifts (fatigue), sudden large eye movements (irritation), or if patients closed their eyes (fatigue). In these cases radiation was reliably interrupted by the gating system. In our clinical setup the novel system for computer-controlled eye movement gated treatments was well tolerated by all patients. The system yields quantitative real-time information about the eye's rotational state with respect to a reference position (treatment planning situation). Together with the possibility of performing movement-gated treatments of uveal melanoma, the system thus greatly improves the quality of this treatment.

Entities:  

Mesh:

Year:  2004        PMID: 15651635     DOI: 10.1118/1.1824195

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma.

Authors:  Toshihiko Inoue; Norihisa Masai; Hiroya Shiomi; Ryoong-Jin Oh; Kenji Uemoto; Noriyasu Hashida
Journal:  J Radiat Res       Date:  2017-05-01       Impact factor: 2.724

2.  Convolutional Neural Networks Cascade for Automatic Pupil and Iris Detection in Ocular Proton Therapy.

Authors:  Luca Antonioli; Andrea Pella; Rosalinda Ricotti; Matteo Rossi; Maria Rosaria Fiore; Gabriele Belotti; Giuseppe Magro; Chiara Paganelli; Ester Orlandi; Mario Ciocca; Guido Baroni
Journal:  Sensors (Basel)       Date:  2021-06-27       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.