Literature DB >> 15651617

A simple method of independent treatment time verification in gamma knife radiosurgery using integral dose.

Jian-Yue Jin1, Robert Drzymala, Zuofeng Li.   

Abstract

The purpose of this study is to develop a simple independent dose calculation method to verify treatment plans for Leksell Gamma Knife radiosurgery. Our approach uses the total integral dose within the skull as an end point for comparison. The total integral dose is computed using a spreadsheet and is compared to that obtained from Leksell GammaPlan. It is calculated as the sum of the integral doses of 201 beams, each passing through a cylindrical volume. The average length of the cylinders is estimated from the Skull-Scaler measurement data taken before treatment. Correction factors are applied to the length of the cylinder depending on the location of a shot in the skull. The radius of the cylinder corresponds to the collimator aperture of the helmet, with a correction factor for the beam penumbra and scattering. We have tested our simple spreadsheet program using treatment plans of 40 patients treated with Gamma Knife in our center. These patients differ in geometry, size, lesion locations, collimator helmet, and treatment complexities. Results show that differences between our calculations and treatment planning results are typically within +/-3%, with a maximum difference of +/-3.8%. We demonstrate that our spreadsheet program is a convenient and effective independent method to verify treatment planning irradiation times prior to implementation of Gamma Knife radiosurgery.

Entities:  

Mesh:

Year:  2004        PMID: 15651617     DOI: 10.1118/1.1824192

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  The variable ellipsoid modeling technique as a verification method for the treatment planning system of gamma knife radiosurgery.

Authors:  Beong Ik Hur; Byung Kwan Choi; Soon Ki Sung; Won Ho Cho; Seung Heon Cha; Chang Hwa Choi
Journal:  J Korean Neurosurg Soc       Date:  2010-02-28

2.  Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique.

Authors:  Beong Ik Hur; Seong Jin Jin; Gyeong Rip Kim; Jong Hyeok Kwak; Young Ha Kim; Sang Weon Lee; Soon Ki Sung
Journal:  J Korean Neurosurg Soc       Date:  2021-01-01

3.  Two-year experience with the commercial Gamma Knife Check software.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Josef Novotny; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.