Pharmacodynamics and pharmacokinetics of high-dose oxycodone infusion during and after coronary artery bypass grafting.

Reino Pöyhiä1, Markku Hynynen, Timo Seppälä, Risto O Roine, Kalervo Verkkala, Klaus T Olkkola.   

Abstract

OBJECTIVE: In small to moderate doses, oxycodone has similar analgesic efficacy to morphine with fewer side effects. The present study evaluated the pharmacokinetics and dynamics of high doses of oxycodone during anesthesia for primary coronary artery bypass grafting.
DESIGN: A randomized, prospective clinical evaluation.
SETTING: A major Scandinavian university clinic. PARTICIPANTS: Two groups with 10 patients each were studied.
INTERVENTIONS: Invasive hemodynamics, echocardiograms, and electrocardiograms were monitored. Oxycodone kinetics, histamine liberation, and plasma cortisol levels were measured. Anesthesia was induced with 1.0 mg/kg of oxycodone and, thereafter, in a random order, maintained with a continuous infusion of oxycodone at a rate of either 0.5 mg/kg/h (group OX 0.5, 10 patients) or 1.0 mg/kg/h (group OX 1.0, 10 patients). An additional bolus dose of 0.5 mg/kg (OX 0.5) or 1.0 mg/kg (OX 1.0) of oxycodone was given before the incision. Enflurane was administered according to hemodynamic criteria.
MEASUREMENTS AND MAIN RESULTS: The induction of and the course of anesthesia were hemodynamically stable in all patients. Enflurane was given to every patient. The mean total doses of oxycodone were 3.5 mg/kg (OX 0.5) and 6.2 mg/kg (OX 1.0). The median t(1/2) of oxycodone varied from 5.1 to 5.9 hours. No hemodynamic differences were found between the groups. No histamine liberation was detected. During anesthesia, the predominant waves in the EEG were theta;- and delta-waves. The mean times to awakening were 3.8 hours and 7.0 hours in the groups OX 0.5 and 1.0, respectively. All patients were intubated until the first postoperative morning. No recall of awareness was reported.
CONCLUSION: A combination of oxycodone and enflurane provides hemodynamically stable anesthesia. No advantages were gained with the higher dose. Elimination of oxycodone was slower than reported previously.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15650985     DOI: 10.1053/j.jvca.2004.08.013

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  4 in total

Review 1.  Translational pain research: evaluating analgesic effect in experimental visceral pain models.

Authors:  Anne Estrup Olesen; Trine Andresen; Lona Louring Christrup; Richard N Upton
Journal:  World J Gastroenterol       Date:  2009-01-14       Impact factor: 5.742

2.  Effects of Transcranial Direct Current Stimulation, Transcranial Pulsed Current Stimulation, and Their Combination on Brain Oscillations in Patients with Chronic Visceral Pain: A Pilot Crossover Randomized Controlled Study.

Authors:  Aurore Thibaut; Cristina Russo; Aura Maria Hurtado-Puerto; Jorge Leon Morales-Quezada; Alícia Deitos; John Christopher Petrozza; Steven Freedman; Felipe Fregni
Journal:  Front Neurol       Date:  2017-11-01       Impact factor: 4.003

3.  Application of oxycodone in anesthesia induction and overall management of Da Vinci robot-assisted nephrectomy: A randomized controlled trial.

Authors:  Haihong Wang; Yuanli Qiu; Qiang Zheng; Yijiao Chen; Liang Ma
Journal:  Medicine (Baltimore)       Date:  2022-08-12       Impact factor: 1.817

4.  Pharmacokinetics of morphine and oxycodone following intravenous administration in elderly patients.

Authors:  Hanne H Villesen; Anne-Marie Banning; Rasmus H Petersen; Sebatian Weinelt; Jesper B Poulsen; Steen H Hansen; Lona L Christrup
Journal:  Ther Clin Risk Manag       Date:  2007-10       Impact factor: 2.423

  4 in total