Literature DB >> 15650065

An in vivo study to compare a plasma arc light and a conventional quartz halogen curing light in orthodontic bonding.

A P Pettemerides1, M Sherriff, A J Ireland.   

Abstract

The purpose of this study was to compare the effectiveness of a plasma arc lamp with a conventional tungsten quartz halogen lamp in orthodontic bonding. Twenty consecutive patients had their brackets bonded either with Transbond XT (n = 10) or Fuji Ortho LC (n = 10). In total, 352 teeth were bonded, 176 in each group. Using a randomized cross-mouth control study design, where diagonally opposite quadrants were assigned a particular treatment, the bonds were then either cured with the control light, namely a halogen lamp, or a plasma arc lamp. The halogen light was used for 20 seconds per tooth and the plasma arc lamp for 3 seconds per tooth. The measurement parameter used was bond failure and the patients were monitored for a period of 6 months following initial bond placement. In the Transbond XT group, the proportion of bond failures was 3.41 per cent for both the halogen and the plasma arc lamp. For the Fuji Ortho LC group, the proportions were 11.4 and 10.2 per cent, respectively. No difference was observed with respect to in-service bond failure proportions between bonds cured with the plasma arc or the conventional halogen lamp, irrespective of the bonding agent. Use of the plasma arc lamp could therefore lead to considerable savings in clinical time. However, this must be weighed against the increased purchase price of the plasma arc lamp.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15650065     DOI: 10.1093/ejo/26.6.573

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Effect of a DPSS laser on the shear bond strength of ceramic brackets with different base designs.

Authors:  Mi-Gyoung Park; Jung-Hoon Ro; Jeong-Kil Park; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

2.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

3.  Use of FT-Raman Spectroscopy to Determine the Degree of Polymerization of Dental Composite Resin Cured with a New Light Source.

Authors:  Safaa K H Khalil; Mousa A Allam; Wael A Tawfik
Journal:  Eur J Dent       Date:  2007-04

4.  Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing.

Authors:  Mohammad Hossein Toodehzaeim; Alireza Danesh Kazemi; Hossein Agha Aghili; Kazem Barzegar; Taranom Fallahtafti
Journal:  Dent Res J (Isfahan)       Date:  2012-05

5.  Clinical performance of uncoated and precoated polymer mesh base ceramic brackets.

Authors:  Hüdanur Yılmaz Née Huda Abulkbash; Selma Elekdag-Türk
Journal:  Prog Orthod       Date:  2019-01-28       Impact factor: 2.750

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.