Literature DB >> 15649035

Latex-coated polymeric monolithic ion-exchange stationary phases. 1. Anion-exchange capillary electrochromatography and in-line sample preconcentration in capillary electrophoresis.

Joseph P Hutchinson1, Philip Zakaria, Andrew R Bowie, Miroslav Macka, Nebojsa Avdalovic, Paul R Haddad.   

Abstract

A sulfonated methacrylate monolithic polymer has been synthesized inside fused-silica capillaries of diameters 50-533-microm i.d. and coated with 65-nm-diameter fully functionalized quaternary ammonium latex particles (AS18, Dionex Corp.) to form an anion-exchange stationary phase. This stationary phase was used for ion-exchange capillary electrochromatography of inorganic anions in a 75-microm-i.d. capillary with Tris/perchlorate electrolyte and direct UV detection at 195 nm. Seven inorganic anions (bromide, nitrate, iodide, iodate, bromate, thiocyanate, chromate) could be separated over a period of 90 s, and the elution order indicated that both ion exchange and electrophoresis contributed to the separation mechanism. Separation efficiencies of up to 1.66 x 10(5) plates m(-1) were achieved, and the monoliths were stable under pressures of up to 62 MPa. Another latex-coated monolith in a 250-microm-i.d. capillary was used for in-line preconcentration by coupling it to a separation capillary in which the EOF had been reversed using a coating of either a cationic polymer or cationic latex particles. Several capillary volumes of sample were loaded onto the preconcentration monolith, and the analytes (inorganic anions) were then eluted from the monolith with a transient isotachophoretic gradient before being separated by electrophoresis in the separation capillary. Linear calibration curves were obtained for aqueous mixtures of bromide, nitrite, nitrate, and iodide. Recoveries of all analytes except iodide were reduced significantly when the sample matrix contained high levels of chloride. The preconcentration method was applied to the determination of iodide in open ocean water and provided a limit of detection of 75 pM (9.5 ng/L) calculated at a signal-to-noise ratio of 3. The relative standard deviation for migration time and peak area for iodide were 1.1 and 2.7%, respectively (n = 6). Iodide was eluted as an efficient peak, yielding a separation efficiency of 5.13 x 10(7) plates m(-1). This focusing was reproducible for repeated analyses of seawater.

Entities:  

Year:  2005        PMID: 15649035     DOI: 10.1021/ac048748d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  New Developments in the Field of Monoliths for Chromatography.

Authors:  Frantisek Svec
Journal:  LC GC Eur       Date:  2010-05-01

Review 2.  Quest for organic polymer-based monolithic columns affording enhanced efficiency in high performance liquid chromatography separations of small molecules in isocratic mode.

Authors:  Frantisek Svec
Journal:  J Chromatogr A       Date:  2011-07-20       Impact factor: 4.759

3.  Collection of peptides released from single neurons with particle-embedded monolithic capillaries followed by detection with matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Yi Fan; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2011-11-22       Impact factor: 6.986

4.  Incorporation of carbon nanotubes in porous polymer monolithic capillary columns to enhance the chromatographic separation of small molecules.

Authors:  Stuart D Chambers; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2011-03-17       Impact factor: 4.759

5.  Preparation of porous polymer monoliths featuring enhanced surface coverage with gold nanoparticles.

Authors:  Yongqin Lv; Fernando Maya Alejandro; Jean M J Fréchet; Frantisek Svec
Journal:  J Chromatogr A       Date:  2012-04-11       Impact factor: 4.759

6.  Porous polymer monolithic column with surface-bound gold nanoparticles for the capture and separation of cysteine-containing peptides.

Authors:  Yan Xu; Qing Cao; Frantisek Svec; Jean M J Fréchet
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

Review 7.  CEC: selected developments that caught my eye since the year 2000.

Authors:  Frantisek Svec
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

Review 8.  Porous polymer monoliths: amazingly wide variety of techniques enabling their preparation.

Authors:  Frantisek Svec
Journal:  J Chromatogr A       Date:  2009-10-02       Impact factor: 4.759

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.